PAR6 Collaborative Arm: print and assemble, configure STEPFOC, install the RCB and bring up the control system
PAR6 is Source Robotics' newer open-source robot-arm platform for research, education and Physical AI. Its beta design uses six STEPFOC closed-loop motor controllers, a CAN bus and a separate Robot Control Box (RCB) with a Raspberry Pi 5. This is not the same electronics stack as the PAROL6 desktop arm.
The project's use of the word “collaborative” does not by itself establish certified human-contact safety. The steps below cover supported, isolated engineering tests rather than an assumption of safe human–robot physical interaction.


1. Components and architecture unique to PAR6
| Subsystem | Function |
|---|---|
| Six motorized joints | Articulated robot motion |
| Six STEPFOC drivers | Closed-loop actuator control with position and fault feedback |
| CAN bus | Communication between control box and joint drivers |
| Raspberry Pi 5 | Computing inside the robot control box |
| RCB electronics | Power distribution and controller I/O |
| RCB Runtime | Real-time control processes and command execution |
| URDF / MuJoCo files | Robot representation for simulation and testing |
| Web operator interface | Diagnostics and control commands |
Obtain the correct arm and RCB hardware revisions together. An incomplete beta mechanical release cannot prove that the control software or safety chain is ready for a physical motion test.
2. Download PAR6's actual mechanical and configuration files
git clone https://github.com/Source-Robotics/PAR6-Collaborative-Robot-Arm.git
cd PAR6-Collaborative-Robot-Arm
ls| File or folder | Contents |
|---|---|
3D Print Files/ | STL and 3MF mechanical files |
BOM/ | Bill of materials and parts links |
Assembly manual/ | Mechanical assembly instructions |
par6_description/ | Mechanical robot description resources |
beta_guide.md | Beta-specific caveats and procedures |
| Separate RCB Runtime repository | System scripts and controller services |
Print projects are published for 250 × 210 mm and 250 × 250 mm plates. Use each part's specific print instructions rather than copying Faze4's reducer settings. Consult the separate robot description repository when you need the latest URDF / MuJoCo and tool variants.
3. Hardware bill of materials and workshop tools
The complete system requires printable structural parts, motors and transmission parts, six STEPFOC modules, correct motor harnesses, CAN wiring and termination, 24 V power components, an RCB board, a Raspberry Pi 5, the robot control enclosure and proper safety-related electrical parts.
The beta BOM also identifies specific Source Robotics PCBs and M8 connectors. Confirm availability and matching versions before buying. For the workshop, prepare an FDM printer, wire crimping tools compatible with the chosen connectors, an appropriately rated power supply, multimeter, hex keys and a rigid mounting frame.
A CAN cable is not interchangeable with an arbitrary three-wire hobby-servo chain. The number of nodes, device addresses and cable termination must match the controller's wiring reference.
4. Build the six-joint mechanism
Diagram A - Mechanical arm breakdown
Open Mermaid source
flowchart TD A["Printed robot base"] --> B["J1: base axis"] B --> C["J2: shoulder"] C --> D["Upper link"] D --> E["J3: elbow"] E --> F["Forearm"] F --> G["J4: wrist"] G --> H["J5: wrist"] H --> I["J6: tool flange"] I --> J["Compatible gripper"]
- Select a matching arm and controller hardware revision and print all specified parts.
- Dry-fit bearings, shafts, couplers and reducer interfaces at the base.
- Mount J1 and confirm its mechanical range without power.
- Build J2 and the upper link while leaving access to the cable channels.
- Assemble J3 and the forearm, then J4–J6 wrist elements.
- Route CAN and motor-power harnesses to avoid snagging through full permitted joint travel.
- Secure the robot to a rigid mounting surface.
- Place the physical stop control outside the reachable robot workspace.
Check shaft alignment, secure fasteners and coupler fit before closing a link. Physical motion is postponed until communications, limits and independent stopping are verified.
5. Robot Control Box: electrical and communication diagram
Diagram B - RCB, CAN, six STEPFOC drives and feedback
Open Mermaid source
flowchart TD PC["Operator control software"] --> R["RCB Raspberry Pi 5"] R --> C["Real-time command loop"] C --> B["CAN interface"] B --> D1["STEPFOC J1"] B --> D2["STEPFOC J2"] B --> D3["STEPFOC J3"] B --> D4["STEPFOC J4"] B --> D5["STEPFOC J5"] B --> D6["STEPFOC J6"] D1 --> F["Motor state and fault feedback"] D2 --> F D3 --> F D4 --> F D5 --> F D6 --> F F --> C P["Rated 24 V supply"] --> G["Actuator power distribution"] G --> D1 G --> D2 G --> D3 G --> D4 G --> D5 G --> D6 X["Independent emergency stop"] --> G
The RCB connects to the Raspberry Pi using the UART interface and exposes a CAN network. Use the released RCB electrical diagrams for correct power distribution, termination, protective devices and emergency stop.
Beta board revisions
Some early RCB boards have factory rework, including jumper wires and modified traces. Preserve those corrections. A newer design drawing must not be treated as permission to remove them from a first-run beta board. Electrical commissioning must be performed with appropriate protective equipment and procedures.
6. Configure each STEPFOC motor driver with MotorGUI
The published beta setup uses MotorGUI and a serial interface to configure drivers individually before connecting the complete CAN network.
- Connect one STEPFOC module to a computer with the specified serial adapter.
- Open MotorGUI and update it to the correct firmware for that revision.
- Select UART communication after the update.
- Load the documented default settings.
- Choose the joint-specific preset, for example J1 for the base driver.
- Set the corresponding CAN identifier.
- Save motor parameters.
- Run the documented
Run #Caloperation in the calibration tab. - Save the calibration result and repeat for every driver.
- Record the final joint-to-driver mapping for the RCB configuration.
Having all six devices respond on the CAN bus does not establish correct axis directions or physical stopping behavior.
7. Install the Raspberry Pi 5 real-time system
The RCB Runtime reference uses Ubuntu 24.04.2 with a PREEMPT_RT kernel, Python 3.11, SocketCAN can0 at 1 Mbit/s and UART /dev/ttyAMA0. Check your image rather than assuming it matches the reference.
uname -r
cat /sys/kernel/realtimeThe reference image reports 6.8.4-rt11-raspi for the kernel and 1 for real-time support. Review system_setup/boot_config.txt in the RCB Runtime repository for required overlays. Do not blindly overwrite the complete /boot/firmware/config.txt; local CAN and UART hardware variants can differ.
8. Download RCB Runtime and run its diagnostics
git clone https://github.com/Source-Robotics/RCB-Runtime.git
cd RCB-Runtime
PYTHON=/usr/bin/python3.11 ./scripts/install.sh./scripts/check_system.pyThe upstream project cautions that the full installation has not been validated on every clean system image. If an install step fails, check the available Python environment, UART/CAN interfaces and its documented prerequisites before attempting motor movement.
9. Launch the three RCB software processes in order
The reference development setup starts the real-time interface first because it creates the shared-memory regions used by the subsequent services.
cd ~/RCB-Runtime
source .venv/bin/activate
python3 RTI.pycd ~/RCB-Runtime
source .venv/bin/activate
python3 command_executor.pycd ~/RCB-Runtime
source .venv/bin/activate
python3 nicegui_test.pyThe reference dashboard uses port 8081. These processes can become capable of commanding real motors, so start with the actuator supply isolated until the complete commissioned safety system is verified.
10. Validate the configuration XML before enabling movement
| Path | Purpose |
|---|---|
config/system.xml | Selected robot and gripper |
robots/<name>.xml | Joint geometry and travel limits |
grippers/<name>.xml | Selected end-effector parameters |
data_recipe/*.xml | Telemetry/data recipes |
Save the following Python file as check_par6_xml.py in the runtime root:
from pathlib import Path
import xml.etree.ElementTree as ET
root = Path(".")
paths = [root / "config" / "system.xml"]
paths += list((root / "robots").glob("*.xml"))
paths += list((root / "grippers").glob("*.xml"))
for path in paths:
try:
document = ET.parse(path)
print("OK", path, document.getroot().tag)
except ET.ParseError as exc:
print("INVALID", path, exc)python3 check_par6_xml.pyThis program only checks XML syntax. It does not validate true motor limits, mechanical clearances, emergency-stop functions or controller behavior.
11. Reference and move a single joint, only after validation
Diagram C - PAR6 pre-motion validation gate
Open Mermaid source
flowchart TD
A["RCB and Pi running"] --> B["Six CAN STEPFOC drivers detected"]
B --> C["Validate emergency-stop circuit"]
C --> D["Verify axes and joint limits"]
D --> E["Load correct robot configuration"]
E --> F["Restricted one-joint motion"]
F --> G{"Correct physical response?"}
G -- No --> H["Stop and diagnose"]
H --> D
G -- Yes --> I["Documented homing"]
I --> J["Check measured positions"]
J --> K["Supervised trajectory"]The RCB interface documents operations including home, jog, move_joints, get_joints and get_status. Their complete connection signatures depend on the installed runtime. Use the actual dashboard or the matching runtime interface, not the PAROL6 API calls.
Inspect measured positions and faults with motor power disabled first. Then validate the circuit's stopping behavior under the documented procedure before a short supported movement. A beta release cannot establish force-limited human interaction without a separate risk assessment and safety validation.
12. Use the robot descriptions and MuJoCo for Physical AI experiments
PAR6 provides robot descriptions in URDF and MuJoCo formats. These are for inspecting geometry, joint limits, simulation behavior and tool-specific models before real deployment.
Diagram D - Simulation-to-physical PAR6 workflow
Open Mermaid source
flowchart TD A["URDF or MuJoCo description"] --> B["Simulated joint motion"] B --> C["Task definition"] C --> D["Manipulation planning or policy"] D --> E["Simulated tests"] E --> F["Check limits and collisions"] F --> G["RCB Runtime"] G --> H["Physical PAR6"] H --> I["Actuator feedback"] I --> G
For a first research task, start without fragile objects, use a supported gripper and fixed camera and compare motion bounds between simulation and hardware. Dataset collection and VLA training need separate validated capture hardware and model configurations; they are not automatically installed by the RCB runtime.
13. Diagnose PAR6's CAN, runtime and mechanical errors
| Failure | What to inspect |
|---|---|
can0 missing | SPI overlay, CAN adapter, operating system configuration |
| STEPFOC node not detected | Bus termination, power, node CAN address |
| RCB link fails | /dev/ttyAMA0 availability and UART settings |
| Linux access denied | Device permissions and user groups |
| Runtime cannot launch | Python 3.11, requirements and XML settings |
| Operator UI shows no data | RTI and command executor running in the correct order |
| Motor direction incorrect | STEPFOC joint preset, motor calibration and coupler mounting |
| Command stopped | Safety stop, joint limits or drive fault |
| Simulated and physical pose differ | Gear ratio, joint zero and geometrical model |
Keep a log of firmware versions, CAN addresses and calibration. Change one motor or controller parameter at a time, then retest its feedback before editing other axes.
14. Beta limitations and verification conditions
The original PAR6 beta release and RCB development guides include revision-specific assembly details. The hardware uses closed-loop control, but normal software feedback and independent stopping are separate functions. A successfully read joint position does not prove the stop system can protect a person.
Keep the development workspace isolated during initial motion, do not test collisions against people and do not call the beta robot certified for collaborative operation. Refer to the actual RCB and STEPFOC electrical diagrams before assembling the power wiring.
Official technical sources: Source-Robotics/PAR6-Collaborative-Robot-Arm, Source-Robotics/RCB-Runtime, Source-Robotics/RCB-Robot-Control-Box and STEPFOC documentation. CAD illustrations are explicitly marked as designs, not photographs. No physical motion test is claimed.
Complete practical guide: PAR6 Collaborative Arm
PAR6 is a collaborative-arm project with a separate robot control box. A mechanical beta release is insufficient evidence of certified collaborative behavior.
1. Files, parts and fabrication
- Select the arm and RCB release together. Inspect the beta drawings, BOM and manufacturing material before printing or ordering parts.
- Dry-fit shafts, bearings and actuator couplers; check the alignment and cable channels at each joint before closing a link.
- Anchor the base and locate the physical stop control outside the arm's reachable envelope.
2. Software installation and configuration
- Use the RCB software and firmware specified for the chosen arm release. Maintain separate records for controller settings and mechanical revision.
- Verify communications, joint order, axes, zero offsets and configured travel. Follow only the published controller procedure.
- Identify the documented stop circuit and motion restriction before issuing any motor target; missing safety specifications block hardware operation.
Commissioning diagram
- 1RCB controller
- 2Joint targets and limits
- 3Actuator motion
- 4Position and fault feedback
- 5Independent stop
Mermaid diagram source
flowchart TD
N0["RCB controller"]
N1["Joint targets and limits"]
N2["Actuator motion"]
N3["Position and fault feedback"]
N4["Independent stop"]
N0 --> N1
N1 --> N2
N2 --> N3
N3 --> N43. Power-on preparation and first movement
- Inspect and test the physical stop circuit through the documented procedure while unintended motion is prevented.
- Confirm the mechanical reference and controller state with a supported unloaded arm. Review diagnostic feedback for each joint.
- Use a single restricted pose from the official interface only after a qualified commissioning check; avoid people in the work envelope.
4. Programming exercise
Record the joint feedback at each repeated pose. This offline example calculates tracking error from measured values without connecting to RCB.
target = list(map(float,input('Target joint angles: ').split()))
observed = list(map(float,input('Observed joint angles: ').split()))
assert len(target)==len(observed) and target
errors = [abs(a-b) for a,b in zip(target,observed)]
print('Absolute errors:', errors)
print('Largest joint error:', max(errors))Compare errors with the acceptance limits defined for the exact arm release. A low joint error does not establish that contact with people is safe.
5. Progress to practical operation
- Verify a restricted unloaded pose and documented stopping behavior before any trajectory.
- Repeat a short sequence within an isolated work area and log measured position and faults.
- A collaborative task requires a separate risk assessment and validation of force, speed and stopping. Do not present beta hardware as certified.
6. Software and hardware diagnostics
- RCB reports joint mismatch
- Check actuator order, firmware revision and calibration.
- Stop behavior cannot be verified
- Keep drives unpowered until the independent safety system is checked.
- Position error increases under motion
- Inspect mechanical couplers and drive faults before another attempt.
Technical basis: PAR6 beta hardware and RCB controller documentation. Programming examples are identified as simulation, offline analysis or documented interface instructions. No physical commissioning test is claimed.
PAR6 beta mechanics and its separate control box
Beta hardware: commissioning requires review
The project is a beta design; the name does not establish certified collaborative operation or permission to run near people.
From parts to first test 5 steps
Review the beta guide before ordering
Read the known issues and compatibility notes. Decide whether the published revision is sufficiently complete for your intended build.
Reference 5 ↓Order the mechanical and control hardware
Use the BOM to pick the correct shaft couplers, bearings, actuators and fasteners. Include the separate RCB control box and its required parts.
Reference 2 ↓Fabricate and assemble the arm
Use the 3D Print Files and assembly manual to check dimensions and shaft fit, assemble successive joints and route cables.
Reference 3 ↓Build or obtain the RCB controller
Follow the separate Robot Control Box repository's electronics and software setup, verifying its wiring against the PAR6 beta revision.
Reference 4 ↓Test in an isolated workspace
Secure the base and verify limits and emergency-stop behavior before any joint movement. Do not use the robot in a collaborative setting without an independently validated safety system.
Reference 5 ↓
Parts, files and official manuals 5 references
Beta arm and separate control box
Practical implementation notes for PAR6 Collaborative Arm. Use the exact hardware and software revision specified in the project documentation.
Tools and equipment
- 3D printer
- caliper
- torque tools
- multimeter
- RCB parts and controller tools
- suitable mounting plate
Component illustration
- 1Base plate
- 2Coupler
- 3Bearing + link
- 4Tool flange
Control architecture
- 01Command interface
- 02RCB controller
- 03Joint drives
- 04PAR6 links
Mechanical preparation and assembly
Review beta release notes and print files before ordering. Dry-fit actuator couplers, bearings and shafts. Assemble structural links in the manual's sequence, making sure each joint and cable channel is accessible for inspection.
Electrical setup and calibration
Build or acquire the matching Robot Control Box. Follow its wiring diagram, check actuator channels, power supply and stop circuit. Verify each documented limit input with motor power isolated. Do not operate near people because beta hardware is not safety-certified by its name.
Software setup and programming
Install the RCB software for the matched arm release. Inspect its joint map and motion limits, then use its documented interface with no payload and a restricted test envelope. Missing commissioning or safety information is a reason to keep hardware unpowered.
First test and acceptance criteria
Verify isolation, stop behavior and zero-command behavior before any motion. Independent risk assessment and safety validation are required before collaborative operation; a bench test is not certification.
Programming and configuration example
This example is an editorial checklist, not a safety interlock or substitute for a qualified commissioning procedure.
# Offline commissioning checklist; all must be verified separately.
checks = ['base secured', 'joint map verified', 'stop circuit tested', 'workspace isolated']
passed = all(input(f'{item}: yes/no? ').strip().lower() == 'yes' for item in checks)
print('Review motion procedure' if passed else 'Keep drives disabled')Troubleshooting
If the stop circuit cannot be tested independently, keep drives disabled. If a beta mechanism or controller configuration is incomplete, do not substitute undocumented limits.
Technical reference: project release documentation. The assembly references above provide the revision-specific drawings and BOM. Examples are editorial walkthroughs or documented commands; they have not been physically tested by TechniaHQRobot.
What is actually published in the beta
The repository separates printable geometry, assembly notes, a BOM and a URDF description. The manufacturer labels the build as beta and asks users to report missing files and incorrect quantities.
Some PCB components are described as available from the vendor during the beta. A link to firmware does not guarantee that every circuit-board manufacturing asset has been released.
A two-part hardware build
Mechanical assembly covers the arm and its cable routing. The motor-control hardware lives in the separate Robot Control Box project, which has its own BOM, wiring and setup information.
Check the chosen shaft-coupler option against the alternate arm STL files: the BOM explains that one option is more prone to slipping and requires different upper-arm parts.
Commissioning with a conservative test sequence
Follow the official cable-building videos and verify connector orientation. The builder warning describes hazardous voltages, so enclosure and isolation checks are part of the build.
Only after hardware checks should the robot description be used for trajectory planning. The beta status means documented configurations may change.
Parts lists, shaft couplers and beta limitations
Answers are based on published source material and project documentation. Their order does not represent search volume.
01Is PAR6 a finished production design?
The project labels itself beta. Its public list of open work includes BOM quantities, 3MF printing resources and documentation fixes. Treat a build as development hardware.
Sources Official project documentation
02Do the STLs include everything needed for operation?
No. The separate Robot Control Box and its electronics are required, and the repository lists additional bought components in its BOM.
Sources Official project documentation
03Which shaft coupler should I choose?
The BOM describes recommended and alternate J2/J3 couplers. The cheaper flange-style alternative is more susceptible to slipping and requires alternate upper-arm STL geometry.
Sources Official project documentation
04Are all electronics manufacturing files released?
The beta BOM notes some boards as vendor-only. Inspect the RCB and driver repositories rather than assuming that every PCB and complete wiring assembly is downloadable.
Sources Official project documentation
05Can I use the PAR6 description for simulation?
The repository includes robot-description resources. They describe joint geometry but cannot verify a physical build's calibration or collision behavior.
Sources Official project documentation
06What electrical warning should builders read?
Source Robotics explicitly warns of hazardous voltages and the risks of a beta-stage design. Read its safety disclaimer before power work.
Sources Official project documentation
PAR6 Collaborative Arm: parts cost, software updates and maintenance
This practical ownership section complements the original assembly and programming instructions. Public files do not guarantee that all components can still be purchased or that every build is supported.
| Item | Project record |
|---|---|
| Cost record / BOM target | No verified full beta-build price |
| Software licence | Repository source terms vary by component; inspect controller/software repositories |
| Hardware licence | CERN-OHL-S-2.0 (PAR6 repository) |
| Simulation availability | PAR6 Description folder includes URDF resources |
| Build difficulty | Advanced |
How to obtain the robot or its parts
Use the PAR6 Collaborative Arm documentation and hardware release to identify whether an assembled product, kit or self-sourced parts are offered. Price the matching revision, not a photograph or an old bill of materials. Include actuators, controller, supply, wiring, tools, fabrication, shipping, tax and spare parts. A historical BOM target is not a current delivered quote.
- Project documentation
- Source repository and version history
- CAD / fabrication files
How the hardware and software work together
Mechanical path: Base plate → Coupler → Bearing + link → Tool flange.
- Command interface
- RCB controller
- Joint drives
- PAR6 links
Feedback, fault detection and the approved stop function constrain the command path.
Install the RCB software for the matched arm release. Inspect its joint map and motion limits, then use its documented interface with no payload and a restricted test envelope. Missing commissioning or safety information is a reason to keep hardware unpowered.
Install, update and recover the software
Keep the exact hardware revision, repository commit, operating system, dependencies, controller firmware and calibration in a local build manifest. Read the project’s setup instructions before installing. Use an isolated environment and a separate checkout for upgrades; compare release notes, regenerate only the documented configuration, and first repeat a simulation or read-only test. Back up calibration and original firmware files where the project supports it. Restore only a documented compatible release if the new version fails.
Project-specific verification: Verify isolation, stop behavior and zero-command behavior before any motion. Independent risk assessment and safety validation are required before collaborative operation; a bench test is not certification.
Power, battery replacement and cycle life
Use the documented external drive power; a mobile configuration needs its own validated supply.
A fixed external power supply is not a rechargeable pack. Battery runtime and charge-cycle count are not applicable to a mains-powered configuration. If a mobile conversion adds a pack, it needs its own rated power system.
Common problems, wear and service plan
| When | Inspection and evidence |
|---|---|
| Before operation | Check couplers, bearing alignment, RCB/STEPFOC configuration and measured position error. An open design alone does not certify collaborative safety. |
| After a fault or impact | Build or acquire the matching Robot Control Box. Follow its wiring diagram, check actuator channels, power supply and stop circuit. Verify each documented limit input with motor power isolated. Do not operate near people because beta hardware is not safety-certified by its name. |
| After software or parts change | Record versions and replaced part serials; compare the same approved test with the earlier baseline. Stop on new errors or unexpected movement. |
| At manufacturer service intervals | Use the documented interval and authorized service procedures. No universal calendar or lubricant is assumed. |
| At end of service | Ask about spare-part availability, data removal, battery take-back and local electronics recycling. |
What is not established by the published files
The project documentation must provide any claimed rated service life, battery cycle endurance, duty limits, warranty and repair intervals for the exact hardware. Without a cited endurance test, report those values as not established, not zero and not an estimate. For a DIY build, keep a parts-replacement log and report conditions when measuring reliability.
Original documentation
- Official source repository
- Assembly documentation
- Printable mechanical files
- Component list
- Separate robot control box
- Beta and known issues
Found a changed specification? Submit a correction with its source ↗