LEAP Hand V1: print and assemble 16 Dynamixel joints, wire and program each finger
Carnegie Mellon LEAP V1 is a sixteen-axis hand with direct Dynamixel motor-in-joint actuation. This independent guide covers printed components, precise motor IDs, source horn alignment, USB power and Python, plus simulated trajectories.

Full and Lite hardware and the sixteen-joint map
LEAP Hand V1 from Carnegie Mellon is an anthropomorphic four-finger robotic hand with 16 individually controlled joints. Choose Full XC330-M288-T or Lite XL330-M288-T motor variants; their electrical and performance limits differ. The V1 CAD is distributed under noncommercial terms separate from the MIT SDK.
| Finger | Motor IDs |
|---|---|
| Index | 0, 1, 2, 3 |
| Middle | 4, 5, 6, 7 |
| Ring | 8, 9, 10, 11 |
| Thumb | 12, 13, 14, 15 |
| Part | Function |
|---|---|
| 16 XC330-M288-T or XL330-M288-T | Joint actuation |
| Right or left palm | Mounting and motor housing |
| MCP/PIP/DIP brackets and spacers | Finger link assemblies |
| Motor horns and idlers | Mechanical torque coupling |
| U2D2 and 5 V supply | USB serial communication and motor power |
| Screws and threaded inserts | Mechanical assembly |
| DYNAMIXEL Wizard and Python SDK | ID setup and software control |
Get the correct right/left CAD, API and tools
mkdir -p ~/leap-hand
cd ~/leap-hand
git clone https://github.com/leap-hand/LEAP_Hand_API.git
cd LEAP_Hand_APIThe official CAD page v1.leaphand.com/leap_cad provides separate left and right URDF/STP and printable palm, cable spacer, MCP bracket, DIP spacer, fingertips and mounting lids. A left-hand thumb differs from a right-hand thumb. Pick the mounting plate matching the attached robot arm.
The Full V1 BOM historically used 16 XC330-M288-T actuators and a 5 V 30 A supply. Follow the published source-specific quantities and use the correct power distribution. Do not treat the Lite motors as drop-in equivalents without comparing torque and current.
Print palm, brackets and fingertips
| Published V1 profile | Original example |
|---|---|
| Palm in PLA | 60% infill with supports |
| Other rigid PLA parts | 100% infill with no supports where specified |
| Typical PLA print | 200 °C nozzle, 60 °C bed |
| Optional NinjaFlex Edge fingertips | 20% infill, 240 °C nozzle and 60 °C bed |
These are documented source profiles for particular materials/printers, not universal print settings. Verify print dimensions and motor bracket fit, and adjust for different filament brands or machines.
Assemble three fingers and the thumb
The original assembly uses FPX330 S101/S102 brackets, H101 motor horns, idlers and M2 fasteners. The horn index marks must correspond to the project home position before final attachment. A wrong 90° or 180° horn alignment cannot be made safe by a large software correction.
For an official finger build, attach the MCP-side bracket, install the PIP servo and horn assembly, then DIP servo and fingertip. The thumb uses a different geometry and must follow its dedicated picture sequence.
Wiring, serial bus and servo identification
Connect the specified 5 V supply and the U2D2 USB adapter according to the published V1 diagram. Avoid motor hot-plugging. Use DYNAMIXEL Wizard to assign IDs 0–15, with three regular finger blocks and the thumb block. Close Wizard before launching Python because it holds the serial port.
ls /dev/serial/by-id/
ls /dev/ttyUSB*Install SDK and read joint positions
cd ~/leap-hand/LEAP_Hand_API/python
python3 -m venv .venv
source .venv/bin/activate
python -m pip install --upgrade pip
python -m pip install dynamixel_sdk numpyimport leap_hand_utils.leap_hand_utils as lhu
leap = lhu.LeapNode()
positions = leap.read_pos()
print('Motor joint positions:', positions)Before running LeapNode, set the correct serial device and current limits in the source configuration. Some SDK initializers activate servo torque; secure the hand first. A successful read should return values for the sixteen configured joints.
First supported home and movement commands
import numpy as np
import leap_hand_utils.leap_hand_utils as lhu
leap = lhu.LeapNode()
target = np.pi * np.ones(16)
leap.set_allegro(target)The Allegro-compatible coordinate convention differs from raw Dynamixel encoder units. The V1 mechanical 180-degree horn reference is not automatically equivalent to a numerical position in every API representation. Only send a verified home pose after checking the actual SDK conversion and all limits.
Preview a sixteen-axis trajectory without motors
import numpy as np
start = np.zeros(16)
goal = np.zeros(16)
goal[0] = 0.2
trajectory = np.linspace(start, goal, 50)
for target in trajectory:
print(np.round(target, 3))This creates simulated numbers only. Do not send it to a physical hand without converting from the illustrated angle coordinates to the documented API convention and verifying collisions and stop limits.
Isaac Gym simulation and learned policies
git clone https://github.com/leap-hand/LEAP_Hand_Sim.gitpython3 train.py wandb_activate=false num_envs=1 headless=false test=true task=LeapHandRot checkpoint=runs/pretrained/nn/LeapHand.pthThe older simulation uses Isaac Gym Preview 4 and an externally available pretrained checkpoint. Its install and GPU dependencies are not included automatically by running train.py. Newer Isaac Lab workflows should use their independently versioned repository and matching NVIDIA installation.
Finger grasp tests and fault isolation
| Problem | Inspection |
|---|---|
| Missing motor | Dynamixel ID, 5 V supply and cable |
| Wrong finger angle | Motor horn reference and joint sign |
| Port busy | Close DYNAMIXEL Wizard before SDK |
| Fingertip collides | Bracket orientation and joint limit |
| Finger jitter | Servo gains, binding or overloaded current |
| Overload LED | Stop and verify mechanical obstruction |
| Simulation fails | Isaac Gym / CUDA version and checkpoint |
- Select full or lite motors and one hand orientation.
- Download matching palm and finger files.
- Print/test supports and assemble horns at reference.
- Assign motor IDs from 0 to 15.
- Verify 5 V current capacity and serial adapter.
- Read all sixteen joints from the SDK.
- Command a small, validated pose after safety checks.
- Validate a simulated grasp before live teleoperation.
Sources: v1.leaphand.com/assembly, v1.leaphand.com/leap_cad, github.com/leap-hand/LEAP_Hand_API and github.com/leap-hand/LEAP_Hand_Sim. No physical LEAP Hand was tested here.
Complete practical guide: LEAP Hand V1
LEAP Hand V1 uses sixteen motorized joints. Its supported API and servo configuration depend on the V1 hardware and handedness; V2 software should not be installed as a replacement.
1. Files, parts and fabrication
- Download the V1 palm and finger files for the chosen hand. Inspect STL orientation, servo cavities and screw holes in the slicer before printing.
- Obtain the specified servo models, controller interface, mounting hardware and supply. Assign every motor its V1 ID individually before daisy chaining.
- Assemble the proximal finger sections, then outer segments and thumb. Align the horns to the documented reference before installing the palm covers.
2. Software installation and configuration
- Install the V1 LEAP_Hand_API Python dependencies in a dedicated environment. Use the python folder's instructions and inspect main.py before executing it.
- Identify the persistent serial adapter path with ls /dev/serial/by-id on Linux. Set the actual port in the example and close competing servo software.
- Review the API angle convention, array ordering, current and position feedback; the supplied example may power motors on startup.
Commissioning diagram
- 1Python joint angle array
- 2V1 API angle convention
- 3Dynamixel motor bus
- 4Finger joint motion
- 5Position and current feedback
Mermaid diagram source
flowchart TD
N0["Python joint angle array"]
N1["V1 API angle convention"]
N2["Dynamixel motor bus"]
N3["Finger joint motion"]
N4["Position and current feedback"]
N0 --> N1
N1 --> N2
N2 --> N3
N3 --> N43. Power-on preparation and first movement
- Clamp the palm to a fixture with all fingertips unobstructed. Verify each motor ID and neutral horn position while power is disconnected.
- Use the documented V1 read-position interface after the approved bus setup. Check all sixteen feedback values before any commanded motion.
- Test a small motion on one finger using the documented V1 API and verified limits. Keep all other fingers in their checked pose.
4. Programming exercise
Check an angle array for index and length mistakes offline. Use radians or the unit stated by the actual V1 API consistently throughout the exercise.
q = list(map(float,input('16 joint positions: ').split()))
assert len(q)==16
idx = int(input('Joint array index (0-15): '))
assert 0 <= idx < 16
step = float(input('Approved small angle change: '))
q_next = q.copy()
q_next[idx] += step
print([(i,a,b) for i,(a,b) in enumerate(zip(q,q_next)) if a!=b])Only the intended array element should change. Compare the resulting target with that physical joint's calibrated bounds before any use with the controller.
5. Progress to practical operation
- Verify one unloaded finger then the remaining fingers individually. Record position error and current using the V1 feedback calls.
- Test a slow closure around a compliant stationary object after confirming the release direction and stop procedure.
- Develop grasp sequences from recorded, valid poses. Add more objects only after measuring grasp and release repeatability.
6. Software and hardware diagnostics
- USB port disappears
- Check the adapter, supply and persistent device path; close other servo tools.
- Wrong finger moves
- Check the V1 ID-to-array mapping and handedness.
- Finger current rises without motion
- Stop and inspect horn alignment, joint clearance and object contact.
Technical basis: LEAP Hand V1 build instructions and LEAP_Hand_API. Programming examples are identified as simulation, offline analysis or documented interface instructions. No physical commissioning test is claimed.
LEAP Hand V1 parts and sixteen motor IDs
Documented 16-motor DIY hand
The V1 CAD and actuator assembly differ from later LEAP versions. Select handedness first.
From parts to first test 5 steps
Source the 16 actuators and bus hardware
Use the V1 assembly and CAD references for the actuator model, fasteners, power and communication adapter; verify the exact palm configuration.
Reference 2 ↓Print the palm and finger set
Download the V1 files for the chosen handedness. The thumb and palm differ for left/right builds; check parts against the assembly illustrations.
Reference 1 ↓Set IDs and horn orientation
Configure the Dynamixel IDs according to the V1 diagram, one motor at a time. Position the motor horns at the documented 180-degree home alignment before attaching printed parts.
Reference 2 ↓Assemble the fingers and connect the bus
Follow the illustrated sequence and secure cables so finger travel cannot strain the connectors. Check each joint before mounting the next segment.
Reference 2 ↓Install the API and test individual joints
Connect the V1 hand's documented 5 V supply and USB cable. Find the port using Dynamixel Wizard, close the Wizard and enter the port in main.py or ros_example.py. Retain the API's default current limit for the first neutral-position and slow finger tests; check feedback before stronger grasps.
Reference 3 ↓
Parts, files and official manuals 4 references
Sixteen-servo dexterous hand
Practical implementation notes for LEAP Hand V1. Use the exact hardware and software revision specified in the project documentation.
Tools and equipment
- FDM printer
- small hex keys
- screwdriver
- multimeter
- documented 5 V supply
- USB-to-Dynamixel adapter
- Dynamixel Wizard
- Python computer
Component illustration
- 1Palm mount
- 2Proximal joint
- 3Middle joint
- 4Distal finger
Control architecture
- 01Python API
- 02Dynamixel bus
- 0316 servo drives
- 04Finger joints
Mechanical preparation and assembly
Choose the V1 handedness and print the matched palm, thumb and finger parts. Configure every servo ID individually using the assembly diagram; align horns at the V1 specified home angle. Assemble proximal finger units before attaching the outer segments, checking cable slack at each joint.
Electrical setup and calibration
Connect the V1 power and Dynamixel bus. Identify the port in Wizard, close it and edit the API's example port. Check that each ID corresponds to the expected finger and joint. Keep the default current limit; a tighter grasp can generate pinch forces.
Software setup and programming
Install the V1 API dependencies using the repository's instructions. Inspect main.py and its joint-angle conventions before running the sample. Start with an offline angle array check and then compare position, velocity and current in the documented interface. Inspect the Python API example from the V1 checkout, with the serial port set to the persistent device path. The supplied example may energize the servos; review every startup target before use.
First test and acceptance criteria
Use an unobstructed palm fixture, verify feedback for all sixteen joints and test one finger at a time. Stop on unexpected current or failed return to the neutral position. Do not use the V2 API for this V1 hand.
Programming and configuration example
The original V1 SDK example can energize all sixteen servos. Review its startup pose and limits before uncommenting it, and do not substitute V2 firmware.
git clone https://github.com/leap-hand/LEAP_Hand_API.git
cd LEAP_Hand_API/python
# Install dependencies per this folder's README.
# Linux: identify the persistent USB serial path.
ls /dev/serial/by-id
# Edit main.py with that port and review initial targets.
# After supported, current-limited calibration:
# python main.pyTroubleshooting
If motor communication fails, close Dynamixel Wizard and check the persistent port. A horn offset or repeated overload requires a mechanical or limit review before another grasp.
Technical reference: project release documentation. The assembly references above provide the revision-specific drawings and BOM. Examples are editorial walkthroughs or documented commands; they have not been physically tested by TechniaHQRobot.
Choose the left or right mechanical assembly
LEAP's CAD page provides separate right and left assemblies and individual printed-part downloads. Palm, cable spacers, MCP brackets and DIP spacers are listed with quantities, along with URDF and STEP assemblies.
Some mounting-plate STL variants match particular robot arms; select one that corresponds to your wrist interface, rather than printing all top plates.
One hand, sixteen motor IDs
The official V1 assembly divides each finger into motorized joints. Its published mapping uses IDs 0–3 for the index, 4–7 for middle, 8–11 for ring and 12–15 for the thumb.
The motor horns must be mounted in their documented home position. A mechanical offset cannot be corrected safely by guessing a larger software command.
Communication and overload troubleshooting
The V1 API expects a powered Dynamixel chain and USB connection. The project recommends inspecting the serial port with Dynamixel Wizard, then closing Wizard before starting the API to avoid a busy port.
The software repository documents jitter, missing motors and overload errors. These are addressed through horn orientation, correct IDs, cable paths, motor current limits and PID settings.
Serial ports, overloads and CAD permissions
Answers are based on published source material and project documentation. Their order does not represent search volume.
01Where are the printable STL files for LEAP Hand V1?
The official CAD page lists left and right palms, brackets, spacers and top plates as STL and STEP files. Choose parts for one mechanical version.
Sources Official project documentation
02How many motors and what are their IDs?
V1 has 16 Dynamixel joints. The official assembly maps finger IDs in blocks of four: 0–3, 4–7, 8–11 and 12–15.
Sources Official project documentation
03What if a finger is 90 degrees away from its home pose?
Check the actuator horn orientation first. The API troubleshooting guide says a horn may be mounted at the wrong angle.
Sources Official project documentation
04Why does the Python API report a busy port?
Close Dynamixel Wizard before running Python because both cannot own the same serial port at once. Also verify the selected device name.
Sources Official project documentation
05What causes hand jitter or overload?
The V1 SDK recommends adjusting PID gains and respecting current limits. Check mechanical binding before increasing controller gains.
Sources Official project documentation
06Can I sell a hand using LEAP CAD?
The hardware CAD is under CC BY-NC-SA, which restricts commercial use. The API's MIT license does not replace the CAD terms.
Sources Official project documentation
LEAP Hand V1: parts cost, software updates and maintenance
This practical ownership section complements the original assembly and programming instructions. Public files do not guarantee that all components can still be purchased or that every build is supported.
| Item | Project record |
|---|---|
| Cost record / BOM target | Varies by 16 actuators and manufacturing; no independently checked current build total |
| Software licence | MIT (API) |
| Hardware licence | CC BY-NC-SA (CAD; noncommercial) |
| Simulation availability | LEAP_Hand_Sim and Isaac Gym/Isaac Lab resources |
| Build difficulty | Advanced |
How to obtain the robot or its parts
Use the LEAP Hand V1 documentation and hardware release to identify whether an assembled product, kit or self-sourced parts are offered. Price the matching revision, not a photograph or an old bill of materials. Include actuators, controller, supply, wiring, tools, fabrication, shipping, tax and spare parts. A historical BOM target is not a current delivered quote.
- Project documentation
- Source repository and version history
- CAD / fabrication files
- Revision-specific workshop source
How the hardware and software work together
Mechanical path: Palm mount → Proximal joint → Middle joint → Distal finger.
- Python API
- Dynamixel bus
- 16 servo drives
- Finger joints
Feedback, fault detection and the approved stop function constrain the command path.
Install the V1 API dependencies using the repository's instructions. Inspect main.py and its joint-angle conventions before running the sample. Start with an offline angle array check and then compare position, velocity and current in the documented interface. Inspect the Python API example from the V1 checkout, with the serial port set to the persistent device path. The supplied example may energize the servos; review every startup target before use.
Install, update and recover the software
Keep the exact hardware revision, repository commit, operating system, dependencies, controller firmware and calibration in a local build manifest. Read the project’s setup instructions before installing. Use an isolated environment and a separate checkout for upgrades; compare release notes, regenerate only the documented configuration, and first repeat a simulation or read-only test. Back up calibration and original firmware files where the project supports it. Restore only a documented compatible release if the new version fails.
Project-specific verification: Use an unobstructed palm fixture, verify feedback for all sixteen joints and test one finger at a time. Stop on unexpected current or failed return to the neutral position. Do not use the V2 API for this V1 hand.
Power, battery replacement and cycle life
A bench hand needs the documented external motor supply; integration with a mobile robot changes the system power budget.
A fixed external power supply is not a rechargeable pack. Battery runtime and charge-cycle count are not applicable to a mains-powered configuration. If a mobile conversion adds a pack, it needs its own rated power system.
Common problems, wear and service plan
| When | Inspection and evidence |
|---|---|
| Before operation | Inspect finger link clearance, servo horn alignment and grasp position repeatability; preserve all 16 servo mappings when replacing one drive. |
| After a fault or impact | Connect the V1 power and Dynamixel bus. Identify the port in Wizard, close it and edit the API's example port. Check that each ID corresponds to the expected finger and joint. Keep the default current limit; a tighter grasp can generate pinch forces. |
| After software or parts change | Record versions and replaced part serials; compare the same approved test with the earlier baseline. Stop on new errors or unexpected movement. |
| At manufacturer service intervals | Use the documented interval and authorized service procedures. No universal calendar or lubricant is assumed. |
| At end of service | Ask about spare-part availability, data removal, battery take-back and local electronics recycling. |
What is not established by the published files
The project documentation must provide any claimed rated service life, battery cycle endurance, duty limits, warranty and repair intervals for the exact hardware. Without a cited endurance test, report those values as not established, not zero and not an estimate. For a DIY build, keep a parts-replacement log and report conditions when measuring reliability.
Original documentation
- CAD usage rights
- Illustrated full hand assembly
- Printable palm and finger components
- Simulation project
Found a changed specification? Submit a correction with its source ↗