Yale OpenHand Model T: cast flexures, route tendons and control one-motor grasping
The Yale OpenHand Model T's unique floating pulley tree distributes force across four compliant fingers. This guide covers fabrication, tendon routing, actuator variants and the older ROS control interface.

Yale Model T mechanics and differential drive
The Yale GRAB Lab Model T is a four-finger underactuated robotic hand using one motor and a floating pulley-tree differential. The differential shares tendon tension among four fingers while their flexure joints conform to the object. Unlike the 16-motor LEAP hand, it cannot independently command each finger.
| Published characteristic | Model T |
|---|---|
| Fingers | Four underactuated |
| Motors | One Dynamixel XM430 in V2 or older MX-64 |
| Mechanical coupling | Floating-pulley tendon differential |
| Original base diameter | 100 mm |
| Original height | 95 mm |
| Original mass | 490 g |
| Reported holding force | 10–13 N |
Choose design revision and find fabrication files
mkdir -p ~/yale-openhand
cd ~/yale-openhand
git clone https://github.com/grablab/openhand-hardware.git
cd openhand-hardware
lsThe hardware repository hosts many hand designs, not only Model T. Select the Model T revision and the chosen flexure-flexure, pivot-flexure or pivot-pivot finger variant. V2's XM430 motor holder differs from older MX-64 designs. Use the matching assembly PDF for each.
The flexure castings use Hybrid Deposition Manufacturing, a combination of rigid printed parts and compliant urethane material. One generic STL does not substitute for correct mold and flexure fabrication.
Manufacture flexure joints and fingers
Check cure time and mixing ratio from the specific urethane supplier. Inspect the interface between printed links and compliant joints before applying tendon tension. Inadequate curing and excessive bending can crack the flexure or permanently deform it.
If using a pivot-joint variant, the required pin and bearing assembly differs from a full flexure finger. Do not mix parts from two variants without verifying joint dimensions.
Assemble the single-motor pulley tree
The floating differential allows some fingers to stop at object contact while remaining fingers advance. Tendons must be routed through the original pulley tree, not four separate fixed-length cables tied directly to a single output shaft. The order and symmetry of the branches influence how the hand closes.
Check the pulleys for low friction, tendon clearance and correct anchoring. Preload only enough to remove slack without holding flexures permanently bent.
Servo power and data communications
The Dynamixel motor receives external power appropriate to its exact model. The two motor generations are not electrically or mechanically interchangeable without review. Ensure actuator ID, serial baud and bus port match the node config.
Install the legacy OpenHand control package
cd ~/yale-openhand
git clone https://github.com/grablab/openhand_node.git
ls openhand_nodeOpenHand Node is older ROS/Python software supporting Model T, T42 and Model O. It is not a native ROS 2 Jazzy application. Use its documented ROS 1 distribution and Python dependencies, preferably in an isolated compatible environment.
mkdir -p ~/catkin_ws/src
cd ~/catkin_ws/src
git clone https://github.com/grablab/openhand_node.git
cd ~/catkin_ws
catkin_make
source devel/setup.bashThis assumes compatible ROS 1 and required packages have been preinstalled. Before build, verify dependencies and the selected YAML for Model T; hardware mode and ports are not universal defaults.
Start the ROS hand node and inspect services
roslaunch openhand_node openhandNode.py
rosservice listCheck the node README and installed service signatures before moving the physical tendon drive. The command syntax is historical and may need a version-specific launch environment; do not invent service arguments to force a live movement.
Python test trajectory before actuating the tendon
import numpy as np
start_position = 0.0
target_position = 0.2
trajectory = np.linspace(start_position, target_position, 50)
for position in trajectory:
print(round(float(position), 4))This is an unassigned numerical demonstration and does not move a motor. Use the exact XM430 or MX-64 position units and travel bounds before converting the reference into an actuator command. Test the movement without an object first, observing finger symmetry and overload.
Grasping experiments and known limitations
- Test the hand freely opening and closing on a fixture.
- Introduce a light cylindrical item and record the order of finger contact.
- Repeat with a sphere, checking differential tension.
- Inspect tendons for slipping, contact friction and uneven force.
- Compare available servo load/current feedback between tests.
A single underactuated motor does not provide independent finger trajectories for dexterous in-hand rotation. This is a mechanical grasping platform, not a LEAP-style 16-axis position controller.
Troubleshooting and verification
| Failure | What to inspect |
|---|---|
| Only one finger closes | Tendon routing, floating pulley motion or friction |
| Differential sticks | Pulley shaft, bearings and tendon pretension |
| Flexure tears | Urethane curing or overbending |
| Hand does not reopen | Restoring force, friction or slack |
| No serial motor | Adapter, servo ID and model voltage |
| Motor overheats | Contact load, stalled tendon or excessive command |
| ROS node error | Legacy Python/ROS compatibility |
- Choose Model T and exact mechanical revision.
- Fabricate four fingers and compliant joints.
- Assemble motor, pulley tree and all tendons.
- Verify smooth unpowered closure and release.
- Check Dynamixel power and feedback.
- Start compatible OpenHand control environment.
- Test short bounded movements.
- Record grasp results on multiple shapes.
Sources: www.eng.yale.edu/grablab/openhand/model_t.html, github.com/grablab/openhand-hardware and github.com/grablab/openhand_node. Mechanical force data refer to the published revision and are not a guarantee for every custom build.
Complete practical guide: Yale OpenHand Model T
Model T uses an underactuated tendon mechanism and compliant finger joints. Its mechanical differential distributes motion across the fingers, so tendon routing determines how the hand adapts to an object.
1. Files, parts and fabrication
- Identify the Model T release, rigid finger pieces and compliant elements. Print only the parts marked for the documented fabrication process.
- Assemble each finger segment and check its passive bend and return before attaching the tendon. Inspect guides for edges that could damage the line.
- Route the tendon branches through the palm differential, then fit the motor and terminations using the documented anchor positions.
2. Software installation and configuration
- Prepare the original Python or ROS openhand_node environment with compatible PySerial, NumPy and SciPy packages.
- Locate the serial port used by the actuator. Run the repository's read-only scan described in the workshop before sending position targets.
- Inspect the Model T controller implementation and actuator limits; do not reuse assumptions from a separately actuated multi-finger hand.
Commissioning diagram
- 1Motor output
- 2Palm differential
- 3Tendon branches
- 4Compliant fingers
- 5Object contact and release
Mermaid diagram source
flowchart TD
N0["Motor output"]
N1["Palm differential"]
N2["Tendon branches"]
N3["Compliant fingers"]
N4["Object contact and release"]
N0 --> N1
N1 --> N2
N2 --> N3
N3 --> N43. Power-on preparation and first movement
- Fixture the palm and inspect passive return with power disconnected. Check that the tendon neither frays nor snags.
- Use the documented short motor movement with no object. Confirm the tendon release direction before closing the fingers.
- Test closure around a soft object with limited travel; observe whether all fingers release without further motor force.
4. Programming exercise
Record finger displacement during an unloaded close and release. Compare measured return to the starting position rather than assuming all fingers receive equal travel.
start = list(map(float,input('Initial finger positions: ').split()))
end = list(map(float,input('Positions after release: ').split()))
assert len(start)==len(end) and start
for i,(a,b) in enumerate(zip(start,end),1):
print('Finger',i,'return error',abs(a-b))Review any finger that fails to return to its original position. Check slack, tendon routing and compliant elements before increasing motor displacement.
5. Progress to practical operation
- Repeat empty closure and release several times, then compare return errors.
- Try small and larger compliant objects within the documented opening, observing how fingers adapt as contact occurs.
- Evaluate a grasp only after verifying release and the actuator's travel and effort limits.
6. Software and hardware diagnostics
- One finger closes early
- Inspect branch length and differential routing.
- Motor moves but finger does not
- Check tendon anchor, slipping spool and slack.
- Hand fails to open
- Check compliant joint recovery and the release direction without increasing force.
Technical basis: Yale OpenHand Model T construction and openhand_node control software. Programming examples are identified as simulation, offline analysis or documented interface instructions. No physical commissioning test is claimed.
Model T tendon differential and flexure assembly
Documented underactuated hand
Model T revisions differ in actuator fit; choose the XM430 or MX64 configuration only where the design supports it.
From parts to first test 5 steps
Choose the Model T revision and actuator
Use Yale's Model T page to match the bill of materials and design variant, including the motor, printed structures, flexible joint materials, tendon and fasteners.
Reference 2 ↓Fabricate rigid and compliant parts
Use the Model T design directory and its construction procedure for the urethane joint elements. Check flexion and recovery before installing the tendon system.
Reference 3 ↓Build and route the tendon differential
Assemble the fingers and palm according to the design; route the tendons through the differential so the single actuator distributes motion across the fingers.
Reference 2 ↓Configure the actuator and control node
Use openhand_node with its compatible actuator/ROS dependencies and serial configuration. Confirm the motor ID and direction.
Reference 4 ↓Test a low-load grasp
Command small closing/opening movements on a fixture and check tendon tension, finger return and actuator limits before attempting an object grasp.
Reference 4 ↓
Parts, files and official manuals 5 references
Single-actuator tendon differential
Practical implementation notes for Yale OpenHand Model T. Use the exact hardware and software revision specified in the project documentation.
Tools and equipment
- Printer
- urethane casting tools and protective equipment where specified
- scissors/cutters
- hex drivers
- tendon routing tools
- serial adapter and actuator supply
Component illustration
- 1Actuator spool
- 2Tendon branch
- 3Compliant finger
- 4Contact surface
Control architecture
- 01ROS / Python
- 02openhand_node
- 03Single actuator
- 04Tendon differential
Mechanical preparation and assembly
Use the Model T variant drawings to print the rigid parts and prepare the compliant joints as described in the construction guide. Assemble the finger segments and verify their passive recovery. Route the tendon branches through the palm differential and secure terminations in the documented configuration.
Electrical setup and calibration
Fit the specified single actuator and adjust tendon slack equally with the hand unpowered. Ensure the motor's opening/closing direction matches the linkage. Verify the serial interface and actuator ID against the selected openhand_node configuration.
Software setup and programming
Install the project Python or ROS dependencies, including compatible PySerial and NumPy. Inspect the Model T control implementation and the serial configuration. First check the actuator on a fixture; command only a short documented motion before grasping anything.
First test and acceptance criteria
Observe finger closure around a soft object without applying strong force. Uneven branch tension, tendon snagging or failure of the compliant joints to return indicates mechanical adjustment is needed.
Programming and configuration example
Replace YOUR_PORT with the actual serial device. This documented scan discovers the actuator ID; it does not request a grasp.
python -m pip install pyserial numpy scipy
# From openhand_node/src/openhand_node:
python lib_robotis_mod.py -d YOUR_PORT --scanTroubleshooting
If a finger closes earlier than the others, inspect tendon routing and slack at the differential. If the hand does not release, inspect the compliant joint return before commanding more motor force.
Technical reference: project release documentation. The assembly references above provide the revision-specific drawings and BOM. Examples are editorial walkthroughs or documented commands; they have not been physically tested by TechniaHQRobot.
Why one actuator can move four fingers
The Model T's four fingers are mechanically underactuated. A floating pulley-tree differential redistributes motion when individual fingers contact objects, making the hand adaptable without four independent finger servos.
This design offers a different research target from in-hand manipulation hands. The project itself notes that a single actuator limits independent manipulation.
Printed structures and urethane flexures
The hardware repository places printable components within folders for each hand model; the original SolidWorks source also references common finger and coupling assemblies. Assembly guides distinguish pivot and flexure alternatives.
Some finger joints are fabricated using Smooth-On polyurethane and printed molds. Rigid 3D printing alone will not reproduce the compliance described in the project.
Versioned servo and tendon setup
Yale's Model T page offers multiple build revisions. The 2019 guide uses XM430 motors while earlier ones refer to MX-64. Select the hardware guide based on the actual servo.
After printing and casting, route tendons according to the differential guide, then check all four fingers with the smallest practical actuation command.
One-motor behavior, prints and urethane casting
Answers are based on published source material and project documentation. Their order does not represent search volume.
01Does Model T need four motors?
No. Its four fingers are driven by a single actuator through a mechanical pulley-tree differential.
Sources Official project documentation
02Can I print every part from rigid PLA?
No. The compliant flexure design uses polyurethane components and molding methods described in the finger guide.
Sources Official project documentation
03Which Dynamixel should I buy?
Model T has revision-specific guides: newer documentation specifies XM430 and older versions MX-64. Use the exact guide for the chosen build.
Sources Official project documentation
04Why do some fingers stop moving when they touch an object?
The underactuated differential redistributes motion after contact. That is expected behavior, although uneven cable routing can also introduce friction.
Sources Official project documentation
05Where are the STLs and SolidWorks assemblies?
The hardware repository stores them under model-specific folders and shared fingers/common parts. Keep referenced assembly dependencies when opening SolidWorks.
Sources Official project documentation
06Can the hardware design be used commercially?
The published hardware license is CC BY-NC 3.0. It permits reuse under its noncommercial conditions and does not grant unrestricted product resale.
Sources Official project documentation
Yale OpenHand Model T: parts cost, software updates and maintenance
This practical ownership section complements the original assembly and programming instructions. Public files do not guarantee that all components can still be purchased or that every build is supported.
| Item | Project record |
|---|---|
| Cost record / BOM target | No verified current full Model T quote |
| Software licence | Model T control code in separate openhand_node repository; check its license |
| Hardware licence | CC BY-NC 3.0 (hardware) |
| Simulation availability | No official full URDF/MJCF for Model T confirmed in root hardware repo |
| Build difficulty | Advanced |
How to obtain the robot or its parts
Use the Yale OpenHand Model T documentation and hardware release to identify whether an assembled product, kit or self-sourced parts are offered. Price the matching revision, not a photograph or an old bill of materials. Include actuators, controller, supply, wiring, tools, fabrication, shipping, tax and spare parts. A historical BOM target is not a current delivered quote.
- Project documentation
- Source repository and version history
- CAD / fabrication files
- Revision-specific workshop source
How the hardware and software work together
Mechanical path: Actuator spool → Tendon branch → Compliant finger → Contact surface.
- ROS / Python
- openhand_node
- Single actuator
- Tendon differential
Feedback, fault detection and the approved stop function constrain the command path.
Install the project Python or ROS dependencies, including compatible PySerial and NumPy. Inspect the Model T control implementation and the serial configuration. First check the actuator on a fixture; command only a short documented motion before grasping anything.
Install, update and recover the software
Keep the exact hardware revision, repository commit, operating system, dependencies, controller firmware and calibration in a local build manifest. Read the project’s setup instructions before installing. Use an isolated environment and a separate checkout for upgrades; compare release notes, regenerate only the documented configuration, and first repeat a simulation or read-only test. Back up calibration and original firmware files where the project supports it. Restore only a documented compatible release if the new version fails.
Project-specific verification: Observe finger closure around a soft object without applying strong force. Uneven branch tension, tendon snagging or failure of the compliant joints to return indicates mechanical adjustment is needed.
Power, battery replacement and cycle life
Use the external supply rated for the selected actuator and controller.
A fixed external power supply is not a rechargeable pack. Battery runtime and charge-cycle count are not applicable to a mains-powered configuration. If a mobile conversion adds a pack, it needs its own rated power system.
Common problems, wear and service plan
| When | Inspection and evidence |
|---|---|
| Before operation | Inspect tendon stretch, spool routing and compliant fingers; compare closing displacement and contact behavior after tendon replacement. |
| After a fault or impact | Fit the specified single actuator and adjust tendon slack equally with the hand unpowered. Ensure the motor's opening/closing direction matches the linkage. Verify the serial interface and actuator ID against the selected openhand_node configuration. |
| After software or parts change | Record versions and replaced part serials; compare the same approved test with the earlier baseline. Stop on new errors or unexpected movement. |
| At manufacturer service intervals | Use the documented interval and authorized service procedures. No universal calendar or lubricant is assumed. |
| At end of service | Ask about spare-part availability, data removal, battery take-back and local electronics recycling. |
What is not established by the published files
The project documentation must provide any claimed rated service life, battery cycle endurance, duty limits, warranty and repair intervals for the exact hardware. Without a cited endurance test, report those values as not established, not zero and not an estimate. For a DIY build, keep a parts-replacement log and report conditions when measuring reliability.
Original documentation
- All OpenHand printable designs
- Model T official revision and guide list
- Model T design files
- Control node and drivers
- Hardware terms
Found a changed specification? Submit a correction with its source ↗