TECHNIAHQROBOT / INDEPENDENT ROBOTICS REPORTINGENGLISH EDITION / 24 November 2026
ROBOTICS / OPEN PROJECTRobot Hands

Yale OpenHand Model T: STL Fingers, Tendons and Flexure Assembly

Yale's Model T uses one actuator to close four compliant fingers through a pulley-tree differential. It provides a practical comparison with independently motorized dexterous hands: finger contact is partly determined by the mechanics rather than joint-by-joint commands. The project includes design revisions and fabrication guides.

Source repository Documentation CAD and design files
Editorial source check · Project documentation and public files; no physical test claimedRevision and parts availability may change
THE TECHNICAL DOSSIERYale OpenHand Model T
COMPLETE HARDWARE AND SOFTWARE GUIDE

Yale OpenHand Model T: cast flexures, route tendons and control one-motor grasping

The Yale OpenHand Model T's unique floating pulley tree distributes force across four compliant fingers. This guide covers fabrication, tendon routing, actuator variants and the older ROS control interface.

Original Yale Model T four-finger underactuated gripper prototypes
Authentic photograph from the Yale GRAB Lab Model T documentation.
TECHNICAL WORKSHOP / 01

Yale Model T mechanics and differential drive

The Yale GRAB Lab Model T is a four-finger underactuated robotic hand using one motor and a floating pulley-tree differential. The differential shares tendon tension among four fingers while their flexure joints conform to the object. Unlike the 16-motor LEAP hand, it cannot independently command each finger.

Published characteristicModel T
FingersFour underactuated
MotorsOne Dynamixel XM430 in V2 or older MX-64
Mechanical couplingFloating-pulley tendon differential
Original base diameter100 mm
Original height95 mm
Original mass490 g
Reported holding force10–13 N
Single Dynamixel actuatorTendon wound on motor pulleyFloating pulley distribution treeFour compliant flexure fingersObject contact with balanced tensions
Yale Model T mechanics and differential drive - educational functional schematic, not manufacturing or electrical wiring documentation.
TECHNICAL WORKSHOP / 02

Choose design revision and find fabrication files

BASH
mkdir -p ~/yale-openhand
cd ~/yale-openhand
git clone https://github.com/grablab/openhand-hardware.git
cd openhand-hardware
ls

The hardware repository hosts many hand designs, not only Model T. Select the Model T revision and the chosen flexure-flexure, pivot-flexure or pivot-pivot finger variant. V2's XM430 motor holder differs from older MX-64 designs. Use the matching assembly PDF for each.

The flexure castings use Hybrid Deposition Manufacturing, a combination of rigid printed parts and compliant urethane material. One generic STL does not substitute for correct mold and flexure fabrication.

TECHNICAL WORKSHOP / 03

Manufacture flexure joints and fingers

Open Model T CAD and select finger variantMake rigid finger links and flexure moldsPrepare urethane following source material specsCast and cure compliant finger jointsDemold and inspect bondingAssemble four full fingers
Manufacture flexure joints and fingers - educational functional schematic, not manufacturing or electrical wiring documentation.

Check cure time and mixing ratio from the specific urethane supplier. Inspect the interface between printed links and compliant joints before applying tendon tension. Inadequate curing and excessive bending can crack the flexure or permanently deform it.

If using a pivot-joint variant, the required pin and bearing assembly differs from a full flexure finger. Do not mix parts from two variants without verifying joint dimensions.

TECHNICAL WORKSHOP / 04

Assemble the single-motor pulley tree

Install XM430/MX-64 in the selected baseAttach the drive spool and primary tendonMount main floating pulley pairBranch into four finger tendon pathsAdjust pretension and inspect return motionSlowly test closure with power disconnected
Assemble the single-motor pulley tree - educational functional schematic, not manufacturing or electrical wiring documentation.

The floating differential allows some fingers to stop at object contact while remaining fingers advance. Tendons must be routed through the original pulley tree, not four separate fixed-length cables tied directly to a single output shaft. The order and symmetry of the branches influence how the hand closes.

Check the pulleys for low friction, tendon clearance and correct anchoring. Preload only enough to remove slack without holding flexures permanently bent.

TECHNICAL WORKSHOP / 05

Servo power and data communications

Linux computer and Python or ROS 1 nodeUSB to Dynamixel serial adapterXM430 or MX-64 based on revisionMotor output spool and tendonsFour compliant fingers and motor feedback
Servo power and data communications - educational functional schematic, not manufacturing or electrical wiring documentation.

The Dynamixel motor receives external power appropriate to its exact model. The two motor generations are not electrically or mechanically interchangeable without review. Ensure actuator ID, serial baud and bus port match the node config.

TECHNICAL WORKSHOP / 06

Install the legacy OpenHand control package

BASH
cd ~/yale-openhand
git clone https://github.com/grablab/openhand_node.git
ls openhand_node

OpenHand Node is older ROS/Python software supporting Model T, T42 and Model O. It is not a native ROS 2 Jazzy application. Use its documented ROS 1 distribution and Python dependencies, preferably in an isolated compatible environment.

BASH
mkdir -p ~/catkin_ws/src
cd ~/catkin_ws/src
git clone https://github.com/grablab/openhand_node.git
cd ~/catkin_ws
catkin_make
source devel/setup.bash

This assumes compatible ROS 1 and required packages have been preinstalled. Before build, verify dependencies and the selected YAML for Model T; hardware mode and ports are not universal defaults.

TECHNICAL WORKSHOP / 07

Start the ROS hand node and inspect services

BASH
roslaunch openhand_node openhandNode.py
rosservice list

Check the node README and installed service signatures before moving the physical tendon drive. The command syntax is historical and may need a version-specific launch environment; do not invent service arguments to force a live movement.

ROS application or OpenHand APIModel T controller configurationSerial servo position and load commandSingle actuator winds tendonFour flexure fingers close around object
Start the ROS hand node and inspect services - educational functional schematic, not manufacturing or electrical wiring documentation.
TECHNICAL WORKSHOP / 08

Python test trajectory before actuating the tendon

PYTHON
import numpy as np
start_position = 0.0
target_position = 0.2
trajectory = np.linspace(start_position, target_position, 50)
for position in trajectory:
    print(round(float(position), 4))

This is an unassigned numerical demonstration and does not move a motor. Use the exact XM430 or MX-64 position units and travel bounds before converting the reference into an actuator command. Test the movement without an object first, observing finger symmetry and overload.

Read motor position and current feedbackCompute small bounded closing incrementCheck mechanical drive limitsClose incrementally and check finger contactStop on resistance or validated grasp
Python test trajectory before actuating the tendon - educational functional schematic, not manufacturing or electrical wiring documentation.
TECHNICAL WORKSHOP / 09

Grasping experiments and known limitations

  1. Test the hand freely opening and closing on a fixture.
  2. Introduce a light cylindrical item and record the order of finger contact.
  3. Repeat with a sphere, checking differential tension.
  4. Inspect tendons for slipping, contact friction and uneven force.
  5. Compare available servo load/current feedback between tests.

A single underactuated motor does not provide independent finger trajectories for dexterous in-hand rotation. This is a mechanical grasping platform, not a LEAP-style 16-axis position controller.

TECHNICAL WORKSHOP / 10

Troubleshooting and verification

FailureWhat to inspect
Only one finger closesTendon routing, floating pulley motion or friction
Differential sticksPulley shaft, bearings and tendon pretension
Flexure tearsUrethane curing or overbending
Hand does not reopenRestoring force, friction or slack
No serial motorAdapter, servo ID and model voltage
Motor overheatsContact load, stalled tendon or excessive command
ROS node errorLegacy Python/ROS compatibility
  1. Choose Model T and exact mechanical revision.
  2. Fabricate four fingers and compliant joints.
  3. Assemble motor, pulley tree and all tendons.
  4. Verify smooth unpowered closure and release.
  5. Check Dynamixel power and feedback.
  6. Start compatible OpenHand control environment.
  7. Test short bounded movements.
  8. Record grasp results on multiple shapes.

Sources: www.eng.yale.edu/grablab/openhand/model_t.html, github.com/grablab/openhand-hardware and github.com/grablab/openhand_node. Mechanical force data refer to the published revision and are not a guarantee for every custom build.

BUILD / PROGRAM / TEST

Complete practical guide: Yale OpenHand Model T

Model T uses an underactuated tendon mechanism and compliant finger joints. Its mechanical differential distributes motion across the fingers, so tendon routing determines how the hand adapts to an object.

1. Files, parts and fabrication

  1. Identify the Model T release, rigid finger pieces and compliant elements. Print only the parts marked for the documented fabrication process.
  2. Assemble each finger segment and check its passive bend and return before attaching the tendon. Inspect guides for edges that could damage the line.
  3. Route the tendon branches through the palm differential, then fit the motor and terminations using the documented anchor positions.

2. Software installation and configuration

  1. Prepare the original Python or ROS openhand_node environment with compatible PySerial, NumPy and SciPy packages.
  2. Locate the serial port used by the actuator. Run the repository's read-only scan described in the workshop before sending position targets.
  3. Inspect the Model T controller implementation and actuator limits; do not reuse assumptions from a separately actuated multi-finger hand.

Commissioning diagram

  1. 1Motor output
  2. 2Palm differential
  3. 3Tendon branches
  4. 4Compliant fingers
  5. 5Object contact and release
Tendon displacement is shared across the fingers; each contact changes the motion available to the remaining fingers.
Mermaid diagram source
flowchart TD
  N0["Motor output"]
  N1["Palm differential"]
  N2["Tendon branches"]
  N3["Compliant fingers"]
  N4["Object contact and release"]
  N0 --> N1
  N1 --> N2
  N2 --> N3
  N3 --> N4

3. Power-on preparation and first movement

  1. Fixture the palm and inspect passive return with power disconnected. Check that the tendon neither frays nor snags.
  2. Use the documented short motor movement with no object. Confirm the tendon release direction before closing the fingers.
  3. Test closure around a soft object with limited travel; observe whether all fingers release without further motor force.

4. Programming exercise

Record finger displacement during an unloaded close and release. Compare measured return to the starting position rather than assuming all fingers receive equal travel.

Python Offline tendon return analysis
start = list(map(float,input('Initial finger positions: ').split()))
end = list(map(float,input('Positions after release: ').split()))
assert len(start)==len(end) and start
for i,(a,b) in enumerate(zip(start,end),1):
    print('Finger',i,'return error',abs(a-b))

Review any finger that fails to return to its original position. Check slack, tendon routing and compliant elements before increasing motor displacement.

5. Progress to practical operation

  1. Repeat empty closure and release several times, then compare return errors.
  2. Try small and larger compliant objects within the documented opening, observing how fingers adapt as contact occurs.
  3. Evaluate a grasp only after verifying release and the actuator's travel and effort limits.

6. Software and hardware diagnostics

One finger closes early
Inspect branch length and differential routing.
Motor moves but finger does not
Check tendon anchor, slipping spool and slack.
Hand fails to open
Check compliant joint recovery and the release direction without increasing force.

Technical basis: Yale OpenHand Model T construction and openhand_node control software. Programming examples are identified as simulation, offline analysis or documented interface instructions. No physical commissioning test is claimed.

BUILD ROUTE

Model T tendon differential and flexure assembly

Documented underactuated hand

Model T revisions differ in actuator fit; choose the XM430 or MX64 configuration only where the design supports it.

From parts to first test 5 steps

  1. Choose the Model T revision and actuator

    Use Yale's Model T page to match the bill of materials and design variant, including the motor, printed structures, flexible joint materials, tendon and fasteners.

    Reference 2 ↓
  2. Fabricate rigid and compliant parts

    Use the Model T design directory and its construction procedure for the urethane joint elements. Check flexion and recovery before installing the tendon system.

    Reference 3 ↓
  3. Build and route the tendon differential

    Assemble the fingers and palm according to the design; route the tendons through the differential so the single actuator distributes motion across the fingers.

    Reference 2 ↓
  4. Configure the actuator and control node

    Use openhand_node with its compatible actuator/ROS dependencies and serial configuration. Confirm the motor ID and direction.

    Reference 4 ↓
  5. Test a low-load grasp

    Command small closing/opening movements on a fixture and check tendon tension, finger return and actuator limits before attempting an object grasp.

    Reference 4 ↓

Parts, files and official manuals 5 references

WORKSHOP / HANDS-ON GUIDE

Single-actuator tendon differential

Practical implementation notes for Yale OpenHand Model T. Use the exact hardware and software revision specified in the project documentation.

Tools and equipment

  • Printer
  • urethane casting tools and protective equipment where specified
  • scissors/cutters
  • hex drivers
  • tendon routing tools
  • serial adapter and actuator supply

Component illustration

  1. 1Actuator spool
  2. 2Tendon branch
  3. 3Compliant finger
  4. 4Contact surface
Functional component schematic, not a physical photograph, dimensional drawing or complete wiring pinout. Match actual components to the released mechanical drawings.

Control architecture

  1. 01ROS / Python
  2. 02openhand_node
  3. 03Single actuator
  4. 04Tendon differential
Logical command path for this revision. Feedback, safety limits and power connections must be checked against the original documentation.

Mechanical preparation and assembly

Use the Model T variant drawings to print the rigid parts and prepare the compliant joints as described in the construction guide. Assemble the finger segments and verify their passive recovery. Route the tendon branches through the palm differential and secure terminations in the documented configuration.

Electrical setup and calibration

Fit the specified single actuator and adjust tendon slack equally with the hand unpowered. Ensure the motor's opening/closing direction matches the linkage. Verify the serial interface and actuator ID against the selected openhand_node configuration.

Software setup and programming

Install the project Python or ROS dependencies, including compatible PySerial and NumPy. Inspect the Model T control implementation and the serial configuration. First check the actuator on a fixture; command only a short documented motion before grasping anything.

First test and acceptance criteria

Observe finger closure around a soft object without applying strong force. Uneven branch tension, tendon snagging or failure of the compliant joints to return indicates mechanical adjustment is needed.

Programming and configuration example

Replace YOUR_PORT with the actual serial device. This documented scan discovers the actuator ID; it does not request a grasp.

BASH Revision-specific example
python -m pip install pyserial numpy scipy
# From openhand_node/src/openhand_node:
python lib_robotis_mod.py -d YOUR_PORT --scan

Troubleshooting

If a finger closes earlier than the others, inspect tendon routing and slack at the differential. If the hand does not release, inspect the compliant joint return before commanding more motor force.

Technical reference: project release documentation. The assembly references above provide the revision-specific drawings and BOM. Examples are editorial walkthroughs or documented commands; they have not been physically tested by TechniaHQRobot.

Why one actuator can move four fingers

The Model T's four fingers are mechanically underactuated. A floating pulley-tree differential redistributes motion when individual fingers contact objects, making the hand adaptable without four independent finger servos.

This design offers a different research target from in-hand manipulation hands. The project itself notes that a single actuator limits independent manipulation.

Printed structures and urethane flexures

The hardware repository places printable components within folders for each hand model; the original SolidWorks source also references common finger and coupling assemblies. Assembly guides distinguish pivot and flexure alternatives.

Some finger joints are fabricated using Smooth-On polyurethane and printed molds. Rigid 3D printing alone will not reproduce the compliance described in the project.

Versioned servo and tendon setup

Yale's Model T page offers multiple build revisions. The 2019 guide uses XM430 motors while earlier ones refer to MX-64. Select the hardware guide based on the actual servo.

After printing and casting, route tendons according to the differential guide, then check all four fingers with the smallest practical actuation command.

03 / PRACTICAL QUESTIONS

One-motor behavior, prints and urethane casting

Answers are based on published source material and project documentation. Their order does not represent search volume.

01Does Model T need four motors?

No. Its four fingers are driven by a single actuator through a mechanical pulley-tree differential.

Sources Official project documentation

02Can I print every part from rigid PLA?

No. The compliant flexure design uses polyurethane components and molding methods described in the finger guide.

Sources Official project documentation

03Which Dynamixel should I buy?

Model T has revision-specific guides: newer documentation specifies XM430 and older versions MX-64. Use the exact guide for the chosen build.

Sources Official project documentation

04Why do some fingers stop moving when they touch an object?

The underactuated differential redistributes motion after contact. That is expected behavior, although uneven cable routing can also introduce friction.

Sources Official project documentation

05Where are the STLs and SolidWorks assemblies?

The hardware repository stores them under model-specific folders and shared fingers/common parts. Keep referenced assembly dependencies when opening SolidWorks.

Sources Official project documentation

06Can the hardware design be used commercially?

The published hardware license is CC BY-NC 3.0. It permits reuse under its noncommercial conditions and does not grant unrestricted product resale.

Sources Official project documentation

Yale OpenHand Model T: parts cost, software updates and maintenance

This practical ownership section complements the original assembly and programming instructions. Public files do not guarantee that all components can still be purchased or that every build is supported.

ItemProject record
Cost record / BOM targetNo verified current full Model T quote
Software licenceModel T control code in separate openhand_node repository; check its license
Hardware licenceCC BY-NC 3.0 (hardware)
Simulation availabilityNo official full URDF/MJCF for Model T confirmed in root hardware repo
Build difficultyAdvanced

How to obtain the robot or its parts

Use the Yale OpenHand Model T documentation and hardware release to identify whether an assembled product, kit or self-sourced parts are offered. Price the matching revision, not a photograph or an old bill of materials. Include actuators, controller, supply, wiring, tools, fabrication, shipping, tax and spare parts. A historical BOM target is not a current delivered quote.

  • Project documentation
  • Source repository and version history
  • CAD / fabrication files
  • Revision-specific workshop source

How the hardware and software work together

Mechanical path: Actuator spool → Tendon branch → Compliant finger → Contact surface.

Operational signal path (conceptual); not a manufacturer circuit diagram.
  1. ROS / Python
  2. openhand_node
  3. Single actuator
  4. Tendon differential

Feedback, fault detection and the approved stop function constrain the command path.

Install the project Python or ROS dependencies, including compatible PySerial and NumPy. Inspect the Model T control implementation and the serial configuration. First check the actuator on a fixture; command only a short documented motion before grasping anything.

Install, update and recover the software

Keep the exact hardware revision, repository commit, operating system, dependencies, controller firmware and calibration in a local build manifest. Read the project’s setup instructions before installing. Use an isolated environment and a separate checkout for upgrades; compare release notes, regenerate only the documented configuration, and first repeat a simulation or read-only test. Back up calibration and original firmware files where the project supports it. Restore only a documented compatible release if the new version fails.

Project-specific verification: Observe finger closure around a soft object without applying strong force. Uneven branch tension, tendon snagging or failure of the compliant joints to return indicates mechanical adjustment is needed.

Power, battery replacement and cycle life

Use the external supply rated for the selected actuator and controller.

A fixed external power supply is not a rechargeable pack. Battery runtime and charge-cycle count are not applicable to a mains-powered configuration. If a mobile conversion adds a pack, it needs its own rated power system.

Common problems, wear and service plan

WhenInspection and evidence
Before operationInspect tendon stretch, spool routing and compliant fingers; compare closing displacement and contact behavior after tendon replacement.
After a fault or impactFit the specified single actuator and adjust tendon slack equally with the hand unpowered. Ensure the motor's opening/closing direction matches the linkage. Verify the serial interface and actuator ID against the selected openhand_node configuration.
After software or parts changeRecord versions and replaced part serials; compare the same approved test with the earlier baseline. Stop on new errors or unexpected movement.
At manufacturer service intervalsUse the documented interval and authorized service procedures. No universal calendar or lubricant is assumed.
At end of serviceAsk about spare-part availability, data removal, battery take-back and local electronics recycling.

What is not established by the published files

The project documentation must provide any claimed rated service life, battery cycle endurance, duty limits, warranty and repair intervals for the exact hardware. Without a cited endurance test, report those values as not established, not zero and not an estimate. For a DIY build, keep a parts-replacement log and report conditions when measuring reliability.

05 / SOURCES

Original documentation

  1. All OpenHand printable designs
  2. Model T official revision and guide list
  3. Model T design files
  4. Control node and drivers
  5. Hardware terms

Found a changed specification? Submit a correction with its source ↗

← Back to the open-source index

How to install the software mentioned on this page

Choose only the tools required for your project. The commands below describe development and simulation setup, not proof of compatibility with a specific physical robot. Match the versions in the original project and test offline before connecting hardware.

Python Windows, macOS, Linux

Install the Python release required by your robot or library. On Windows use the official installer; on Ubuntu use the distribution package. Create a separate virtual environment for each project.

Installation / setup commands

python -m venv .venv
# Windows PowerShell:
.\.venv\Scripts\Activate.ps1
# Linux or macOS:
source .venv/bin/activate

Verify the installation

python --version python -m pip --version

Official instructions: https://www.python.org/downloads/

Git Windows, macOS, Linux

Install Git from the official download page or your package manager. On Ubuntu the commands below install the command-line client; on Windows run Git for Windows.

Installation / setup commands

sudo apt update
sudo apt install git

Verify the installation

git --version

Official instructions: https://git-scm.com/downloads

ROS 2 (Jazzy example) Ubuntu 24.04 for Jazzy; other distributions have different instructions

On Ubuntu 24.04 first configure the official ROS apt repository using the documented ros2-apt-source procedure. Then install Jazzy desktop. Use the distribution required by your robot; for example Humble normally uses Ubuntu 22.04.

Installation / setup commands

sudo apt update
sudo apt install ros-jazzy-desktop
source /opt/ros/jazzy/setup.bash

Verify the installation

ros2 --help

Official instructions: https://docs.ros.org/en/jazzy/Installation/Ubuntu-Install-Debs.html

ROS 1 (legacy) Legacy Ubuntu 20.04 / Noetic

ROS Noetic has reached end of life. For an archived project, recreate its documented OS and ROS environment in an isolated workspace or container. For new development choose a supported ROS 2 distribution.

Verify the installation

Check rosversion -d in the existing ROS 1 environment.

Official instructions: https://wiki.ros.org/noetic/Installation

SOLIDWORKS Supported Windows workstation

Check the license and system requirements, download the installer using the authorized SOLIDWORKS account, and select the components needed for the CAD project.

Verify the installation

Open a supplied example part.

Official instructions: https://www.solidworks.com/

NumPy Python environment on a supported OS

Use the Python version supported by the project.

Installation / setup commands

python -m pip install numpy

Verify the installation

python -c "import numpy; print('Import OK')"

Official instructions: https://numpy.org/install/

SciPy Python environment on a supported OS

Use the Python version supported by the project.

Installation / setup commands

python -m pip install scipy

Verify the installation

python -c "import scipy; print('Import OK')"

Official instructions: https://scipy.org/install/