UCSD Continuum Actuation: modular linear and rotary drives, assembly, Nanotec EtherCAT and ROS 2 control
The Unified Continuum Robot Actuation Platform is an open-source modular research platform from the Morimoto Lab at the University of California San Diego. It provides actuators, mechanical construction files and motor-control software to drive continuum robots such as tendon-driven continuum robots (TDCR) and concentric tube robots (CTR). It is not a complete standalone autonomous arm.
A module can translate a tendon or a tube while a separate rotary stage rotates a section. The lab documented a configurable assembly, an open hardware BOM and a ROS 2 workspace that talks to Nanotec motor controllers over EtherCAT. The particular number of actuators, tendon routing, end effector and robot backbone depend on the research experiment.


1. What the unified continuum actuation system contains
One documented TDCR example uses four translation stages and one rotation stage on a common frame. Its central channel can carry a camera, surgical forceps or another instrument. The research platform can also be reconfigured for different kinematics and actuator counts.
| Hardware or software | Role |
|---|---|
| Stepper motor | Moves the linear translation module |
| Lead screw, nut and guide rails | Convert motor rotation to controlled displacement |
| Linear stage carriage | Connects actuator movement to a tendon or tube |
| BLDC motor | Provides rotary axis actuation |
| Worm reduction and collar | Couples rotation to tube or support |
| Tendon termination components | Connect the platform to a flexible robot |
| Mechanical front and rear frames | Align and mount the multiple modules |
| Nanotec motor controllers | Drive configuration and motion control |
| EtherCAT adapter and network | Computer-to-controller communication |
| ROS 2 and CRTK interface | Commands, joint-state feedback and teleoperation |
The project's paper reports sub-millimeter translation accuracy and less than 5° rotation error over tested travel ranges of 30 mm and 180°, respectively. Such results only characterize the laboratory's evaluated apparatus, not every self-built instance or tendon configuration.
2. General architecture of a tendon-driven continuum setup
Diagram 1 - Multiple actuator modules feeding one continuum robot
Open Mermaid source
flowchart TD A["Main support frame"] --> B["Linear rails"] B --> C["Translation stages"] D["Stepper motors"] --> E["Lead screws"] E --> C C --> F["Tendon terminations"] F --> G["Tendons in continuum robot"] H["BLDC motor"] --> I["Worm gearbox"] I --> J["Rotary stage"] G --> K["Flexible continuum manipulator"] J --> K
3. Download the official hardware files, BOM and assembly PDF
git clone https://github.com/UCSDMorimotoLab/unified-actuation-hardware.git
cd unified-actuation-hardware
ls| Published file or folder | What to inspect |
|---|---|
CAD_and_print_files/ | 3D printing files and SolidWorks mechanical assemblies |
AssemblyDoc_6-24-2026.pdf | Illustrated fabrication and assembly method |
BOM_6-25-2026.xlsx | Parts quantities, references and sourcing information |
images/ | Original apparatus photographs and diagrams |
README.md | Revision context and complete assembly-video reference |
Select whether you are building a tendon-driven (TDCR), concentric-tube (CTR) or other configuration. The number of translation and rotation channels is determined by the manipulator, not by copying a fixed list from an example illustration.
4. Prepare the BOM, 3D-printed parts and nonprintable components
- Open the procurement spreadsheet and identify all parts needed per actuator channel.
- Open the SolidWorks assembly or a compatible CAD viewer to check units, mounting spacing, hole sizes and maximum translation stroke.
- Identify which brackets and holders can be 3D-printed and which elements need purchased rails, bearings, lead screws or metal shafts.
- Print one actuator mount and check it against the actual hardware before producing all modules.
- Inspect the accuracy of guide-rail seats and lead-screw support positions; misalignment can jam the carriage.
- Prepare the front and rear frame, printed tube collars and cable terminations according to the chosen assembly.
Do not assign a single universal layer height or infill to all components without checking the original manufacturing drawings. This is a configurable actuation platform rather than one finished self-printable robot.
5. Assemble the lead-screw translation module
Diagram 2 - Drive a single tendon termination
Open Mermaid source
flowchart TD A["Stepper motor"] --> B["Lead screw"] B --> C["Nut and moving carriage"] D["Linear guide rails"] --> C C --> E["Tendon termination"] E --> F["Linear displacement"] F --> G["Pull or release tendon"]
- Mount and align the linear guides on the support frame.
- Install the lead-screw bearing supports and motor coupler.
- Insert the lead screw and attach its nut to the moving carriage.
- Move the carriage manually through the permitted stroke to verify parallel alignment.
- Attach the tendon termination, initially with no external cable load.
- Measure displacement and return position using a ruler or suitable sensor.
If a moving stage binds close to an end stop, disconnect actuator power and inspect mechanical travel and alignment before another test.
6. Assemble the rotating tube module
Diagram 3 - BLDC and worm-driven tube rotation
Open Mermaid source
flowchart LR A["BLDC motor"] --> B["Drive transmission"] B --> C["Worm reduction"] C --> D["Rotary shaft"] D --> E["Shaft collar"] E --> F["Continuum tube support"]
Install the rotary bearings, attach the worm reduction and check that the output turns freely without an off-axis load. Tighten the proper shaft collar and verify that it does not crush a delicate tube. Check physical angular stops separately from software limits.
7. Build an example four-translation, one-rotation platform
Diagram 4 - Tendon-driven research configuration
Open Mermaid source
flowchart TD A["Shared assembly frame"] --> T1["Translation 1"] A --> T2["Translation 2"] A --> T3["Translation 3"] A --> T4["Translation 4"] A --> R["Rotary module"] T1 --> C["Tendon-driven continuum robot"] T2 --> C T3 --> C T4 --> C R --> C W["Central camera / tool channel"] --> C
Fit modules in the original frame positions and label the corresponding tendons before connection. Confirm that a motor output cannot pull a tendon in the wrong direction without increasing unwanted antagonistic tension.
8. Nanotec motor controllers and EtherCAT wiring
The upstream software uses Nanotec drivers through the EtherCAT interface. Do not wire motor outputs directly to Raspberry Pi GPIO or substitute hobby-servo bus commands. Select each controller's device ID according to the installed configuration.
Diagram 5 - ROS 2 to motor controller hardware
Open Mermaid source
flowchart TD A["Linux PC with ROS 2"] --> B["Nanotec Nanolib"] B --> C["EtherCAT adapter"] C --> D["Nanotec controllers"] D --> E["Stepper translation motors"] D --> F["BLDC rotation motors"] E --> G["Translation stages"] F --> H["Rotary stages"] G --> I["Continuum robot"] H --> I J["Read positions / motor errors"] --> A
| Motor IDs in source | Motion type | Units | Feedback model |
|---|---|---|---|
S1-S7 | Lead-screw translation | Millimeters | Open-loop stepper as configured in source |
B1-B5 | Tube rotation | Radians | Closed-loop BLDC as configured in source |
The software maps S1-S7 to device IDs 1-7 and B1-B5 to IDs 8-12. Its upstream lab README notes that a full twelve-motor rig would require all three controller boards, whereas the lab's described working configuration only had eight usable motors because one board was out of service. Match motorIDs to actual devices instead of assuming twelve are always connected.
9. Install the ROS 2 software workspace
git clone https://github.com/UCSDMorimotoLab/unified-actuation-software.git
cd unified-actuation-softwareThe repo uses actuation_control_python, a vendored CRTK layer, standard ROS 2 messages, PyKDL, NumPy, the inputs package and Nanotec's separate nanotec_nanolib dependency. Obtain and configure Nanotec's supported software for your EtherCAT hardware; a generic pip command is not guaranteed.
source /opt/ros/$ROS_DISTRO/setup.bash
sudo apt update
sudo apt install -y \
git \
python3-colcon-common-extensions \
python3-numpy
cd ~/unified-actuation-software
colcon build --symlink-install
source install/setup.bashros2 pkg list | grep actuation_control_python
ros2 pkg executables actuation_control_pythonThese commands build and inspect software. No motor is commanded. If compilation fails, inspect the distribution, Python package availability, CRTK messages, PyKDL and Nanotec libraries.
10. Learn the ROS 2 message conventions and motor mapping
For the example namespace TDCR, the controller uses sensor_msgs/JointState messages:
| Topic | Purpose |
|---|---|
/TDCR/setpoint_ms | Desired motor positions ordered as motorIDs |
/TDCR/measured_ms | Feedback positions; effort data are not provided as a load-cell measurement |
Diagram 6 - Setpoint / feedback command path
Open Mermaid source
flowchart TD A["Keyboard / trajectory node"] --> B["TDCR/setpoint_ms"] B --> C["abs_motor_pos_control.py"] C --> D["Nanolib / EtherCAT"] D --> E["Stepper and BLDC stages"] E --> F["Measured positions"] F --> G["TDCR/measured_ms"] G --> H["Observer and diagnostic UI"]
ros2 topic list
ros2 topic info /TDCR/setpoint_ms
ros2 topic info /TDCR/measured_ms
ros2 topic echo /TDCR/measured_msThe CTR namespace is used by related concentric-tube configurations. Do not mix the two namespaces unintentionally.
11. Set motor IDs, EtherCAT devices and control mode correctly
Before starting a hardware controller, edit the module-level motorIDs list in each relevant script to match the actual connected devices. The main low-level node is located under:
src/actuation_control/actuation_control_python/scripts/abs_motor_pos_control.pyThe upstream controller supports two operating modes. The BLOCKING flag selects between the Profile Position operation that waits for a move to complete and the nonblocking Cyclic Synchronous Position (CSP) path that sends streaming position targets.
| Mode | Mechanism | Important condition |
|---|---|---|
BLOCKING = True | Profile Position, relative motion with waiting | Discrete moves, no continuously changing target assumed |
BLOCKING = False | CSP continuous position streaming | Requires properly configured Nanotec operating mode and timing |
The published README describes a nominal 100 Hz low-level cycle. Its CSP implementation streams targets via SDO rather than the conventional cyclic PDO pattern, and the authors note that interpolation settings may need tuning. Confirm the device's operating mode and fault feedback before any real motion.
For translation motors, the example setup uses 2 mm linear feed per motor revolution. For the rotation chain, the example describes a composite 190:1 reduction. These are software reference settings and must not be copied into mechanically different custom modules.
12. Commission the first real actuator using keyboard teleoperation
Physical actuation warning: The following examples can drive motors. Start with one mechanically unloaded translation stage, confirm end stops and appropriate current limits, keep the tendon detached during the first test and use an independent means of cutting power. A working ROS 2 topic is not a validated safety system.
After configuring motor identities, EtherCAT hardware and the controller limits, use two separate terminals with the same namespace.
cd ~/unified-actuation-software
source /opt/ros/$ROS_DISTRO/setup.bash
source install/setup.bash
ros2 run actuation_control_python \
abs_motor_pos_control.py TDCRcd ~/unified-actuation-software
source /opt/ros/$ROS_DISTRO/setup.bash
source install/setup.bash
ros2 run actuation_control_python \
keyboard_command_motor_pos.py TDCR| Control key | Function |
|---|---|
0 through 5 | Select a motor by its index in motorIDs |
w | Increment selected motor position |
s | Decrement selected motor position |
z | Hold for reduced motion increment |
The documented translation example uses a default step of 0.2 mm per keyboard cycle, with a separate scaled step in radians for BLDC. Verify those constants in your actual script and use a smaller verified travel when commissioning a new module. The 0-5 keys refer to list indices rather than hard-coded EtherCAT device IDs.
13. Control antagonistic pairs without overstressing tendons
For a tendon-driven manipulator, one motor can pay in a tendon while another pays out its antagonist. This requires the intended mechanical pair and equal-and-opposite linear displacement commands.
Diagram 7 - Antagonistic tendon motion
Show Mermaid source
flowchart TD A["Bending command"] --> B["Antagonistic motor pair"] B --> C["Motor A: pay tendon in"] B --> D["Motor B: pay tendon out"] C --> E["Differential tendon length"] D --> E E --> F["Continuum backbone bending"]
Use the published antagonistic keyboard node only after verifying the pair order:
ros2 run actuation_control_python \
keyboard_command_motor_pos_pay_in_out.py TDCRThe script expects an even number of entries in motorIDs, with adjacent entries paired as (0,1), (2,3) and so on. A mismatch between software pairs and actual tendons can command two antagonists in the wrong direction.
14. Calculate tendon displacement from a spool's rotation
For a constant-radius spool without slipping, the linear cable displacement is approximately the spool radius times the angular movement in radians:
Linear displacement = effective radius × angular rotation (radians). This is a geometric approximation. Real tendon systems add compliance, backlash and varying curvature.
import math
# Example dimensions; replace with measured values.
spool_radius_mm = 8.0
rotation_degrees = 15.0
angle_rad = math.radians(rotation_degrees)
travel_mm = spool_radius_mm * angle_rad
print("Approximate cable travel:", round(travel_mm, 3), "mm")
print("Antagonistic motor A:", round(-travel_mm, 3), "mm")
print("Antagonistic motor B:", round(travel_mm, 3), "mm")For a lead-screw stage, use its measured feed per revolution to convert commanded rotations to carriage displacement. Validate each stage's stroke against a physical measurement, not a model assumption.
15. Program a controlled periodic movement
The repo includes a sinusoidal setpoint generator. It can create opposing phases for an antagonistic pair, for example 0° and 180°. The parameters amplitudes, frequencies, phases_deg, DURATION_S and RAMP_S must be checked and tailored before the motor controller receives any command.
Diagram 8 - Periodic movement command pipeline
Show Mermaid source
flowchart TD A["Amplitude"] --> D["Sinusoidal command generator"] B["Frequency"] --> D C["Phase"] --> D D --> E["Setpoint vector"] E --> F["Low-level motor control"] F --> G["Translation / rotation"] G --> H["Measured positions"]
ros2 run actuation_control_python \
move_sine_command_motor_pos.py TDCRThis script needs the matching abs_motor_pos_control.py TDCR subscriber to actuate hardware. Its wave is relative to the current motor position, not an automatic return to a mechanical home reference. The released implementation waits for an operator start signal and uses an amplitude envelope.
16. Reference the position before CTR or TDCR manipulation
The upstream source includes two CTR-specific publishing routines:
ros2 run actuation_control_python \
drive_motors_to_home.py CTRros2 run actuation_control_python \
drive_motors_to_start.py CTRThey are not universal hardware homing implementations. For CTR, the lab document describes referencing the translation stages in a sequential limit-switch order and visually aligning the tubes' rotation. The ROS scripts publish configured relative ramps and require adjustment for the actual motorIDs list and starting pose.
The documentation has not supplied a completed TDCR homing procedure. In addition, drive_motors_to_home.py and drive_motors_to_start.py use different indexing offsets when iterating translation stages. Reconcile these loops when adapting motor count. A node named “home” must never be assumed to discover mechanical limits automatically.
17. Monitor the real motor feedback using your own ROS 2 Python script
This example subscribes to position messages without publishing a target or commanding motion. Save as monitor_ucsd_actuation.py in an environment with ROS 2 available.
import rclpy
from rclpy.node import Node
from sensor_msgs.msg import JointState
class MotorMonitor(Node):
def __init__(self):
super().__init__("ucsd_motor_monitor")
self.subscription = self.create_subscription(
JointState,
"/TDCR/measured_ms",
self.report,
10,
)
def report(self, msg):
for index, position in enumerate(msg.position):
name = (
msg.name[index]
if index < len(msg.name)
else f"motor_{index}"
)
self.get_logger().info(
f"{name}: {position:.4f}"
)
def main():
rclpy.init()
node = MotorMonitor()
try:
rclpy.spin(node)
except KeyboardInterrupt:
pass
finally:
node.destroy_node()
rclpy.shutdown()
if __name__ == "__main__":
main()source /opt/ros/$ROS_DISTRO/setup.bash
python3 monitor_ucsd_actuation.pyPositions are in mm for the S translation channels and radians for the B rotary channels according to the published mapping. The lack of a torque sensor means these position logs alone do not reveal excessive tendon tension.
18. Quantify actuator displacement and repeatability
Measure a translation stage's output with a calibrated ruler or sensor after several identical commands. This stand-alone Python program compares repeated strokes with a reference measurement. It does not connect to EtherCAT or publish motor commands.
from statistics import mean, stdev
reference_mm = float(input("Target stroke in mm: "))
samples = list(map(float, input(
"Measured repeated strokes in mm: "
).split()))
assert len(samples) >= 2, "Use at least two measurements."
average = mean(samples)
print("Average stroke (mm):", round(average, 4))
print("Mean error (mm):", round(average - reference_mm, 4))
print("Repeatability SD (mm):", round(stdev(samples), 4))Measure approach from both directions to identify backlash and hysteresis. Once a module's stroke is repeatable, add the independently designed flexible backbone and validate how its actual tip displacement responds to the tendon motion.
19. Troubleshooting and conditions for the first successful demonstration
| Problem | Check |
|---|---|
| No Nanotec controller detected | EtherCAT adapter, drive power, device addressing and Nanolib access |
| ROS 2 build fails | Compatible ROS distribution, CRTK package, PyKDL and Nanotec dependencies |
No measured_ms topic | Low-level node, namespace and running EtherCAT interface |
| Wrong motor responds | Actual device IDs and order in motorIDs |
| Translation direction reversed | Sign conventions and drive setup |
| Stage binds near travel limit | Lead screw, guide rail alignment and end stop |
| Tendon tension increases unexpectedly | Tendon routing, spool, antagonistic pair mapping and command signs |
| Measured position jumps or drifts | Drive operating mode, calibration and motor feedback |
| CTR reference motion is unsafe | cmd_values, stop sensors, motor count and custom home logic |
| Continuum tip follows an unexpected path | Backbone geometry, tendon elasticity, calibration and model mismatch |
The first valid demonstration is one module moving reproducibly within a measured stroke, with correct electrical setup and mechanical stops. Extend to one antagonistic pair and then synchronized stages only after each part has passed individual tests. The laboratory's published accuracy results must not be attributed to untested custom builds.
Official source basis: UCSDMorimotoLab/unified-actuation-hardware and UCSDMorimotoLab/unified-actuation-software, the dated BOM and assembly PDF and the research platform's design paper. This guide does not claim that the hardware was physically assembled, actuated or safety-certified.
Complete practical guide: Unified Continuum Robot Actuation
The UCSD continuum actuation project supplies an actuator subsystem rather than a complete autonomous continuum robot. The first experiment is to measure output displacement and repeatability of one channel.
1. Files, parts and fabrication
- Obtain the released procurement spreadsheet, CAD and assembly PDF. Match each purchased item to one channel before ordering multiple units.
- Use the fabrication material and dimensions listed in the drawings. Fit the moving stage and check its stroke without power; avoid clamping a moving element out of alignment.
- Assemble one channel with its prescribed actuator and mounting hardware before reproducing the remaining channels.
2. Software installation and configuration
- Open the mechanical model in a compatible CAD viewer and confirm units and stroke. Locate the control material supplied for the same revision.
- If a firmware or driver is supplied, install it only using its documented board and configuration. Verify independently measured travel, current and stop limits.
- Create a measurement log for input command, output displacement and return position. Do not assume the actuator provides complete continuum-arm kinematics.
Commissioning diagram
- 1Actuation input
- 2Transmission and moving stage
- 3Tendon or output displacement
- 4Backbone deformation
- 5Measured tip position
Mermaid diagram source
flowchart TD
N0["Actuation input"]
N1["Transmission and moving stage"]
N2["Tendon or output displacement"]
N3["Backbone deformation"]
N4["Measured tip position"]
N0 --> N1
N1 --> N2
N2 --> N3
N3 --> N43. Power-on preparation and first movement
- Mount one channel in a fixture and inspect unloaded movement through its mechanical range with power off.
- Measure displacement and return after repeated limited movements, using an approved procedure only if the controller and limits are documented.
- Add a tendon or backbone load only after verifying the actuator's repeatability and safe travel; avoid unsupported tension assumptions.
4. Programming exercise
Compare measured displacement against a reference across repeated cycles. This exercise processes measured data, not motor commands.
from statistics import mean,stdev
reference = float(input('Reference stroke (mm): '))
samples = list(map(float,input('Measured strokes (mm): ').split()))
assert len(samples)>=2
print('Mean:',mean(samples))
print('Mean error:',mean(samples)-reference)
print('Repeatability SD:',stdev(samples))Bias and spread describe different errors. Check alignment and measurement repeatability before interpreting the result as an actuator-control problem.
5. Progress to practical operation
- Test repeated unloaded actuator displacement with a calibrated ruler or position sensor.
- Characterize return and hysteresis from opposite directions under a separately verified load.
- A complete continuum manipulator requires backbone geometry, tendon layout, sensing and a calibrated tip-motion controller. None of these can be inferred from an actuator-only release.
6. Software and hardware diagnostics
- Output displacement varies
- Inspect alignment, friction, fasteners and measurement method.
- Actuator binds near end of travel
- Stop and inspect the mechanical stroke and control limit.
- Tip motion differs from input
- Check tendon routing, elasticity and the backbone model after separate actuator verification.
Technical basis: UCSD continuum actuation procurement, CAD and assembly release. Programming examples are identified as simulation, offline analysis or documented interface instructions. No physical commissioning test is claimed.
Modular continuum-actuation fabrication and wiring
Research actuator subsystem: not a robot kit
The release supplies an actuation platform for continuum mechanisms, not a complete autonomous robot or ready-to-run application.
From parts to first test 4 steps
Select the required actuation channel configuration
Use the project's parts and procurement spreadsheet to match the required channels, motors, electronics and mechanical components. Confirm the exact design revision before ordering.
Reference 1 ↓Download and manufacture the structural parts
Use the repository's CAD and print files; match parts to the assembly PDF and procure the specified nonprinted components.
Reference 1 ↓Build the actuator hardware from the PDF
Follow the documented mechanical sequence and use the assembly video to check the orientation of less obvious components. Verify free movement before wiring.
Reference 1 ↓Verify electronics and test one channel
Use the released electrical information, check power and controller compatibility, then test a single unloaded actuator at restricted effort. Integration into a continuum robot requires separate mechanism and control design.
Reference 1 ↓
Parts, files and official manuals 1 references
Research actuator channel and tendon travel
Practical implementation notes for Unified Continuum Robot Actuation. Use the exact hardware and software revision specified in the project documentation.
Tools and equipment
- CAD viewer
- FDM printer or fabrication service specified by the release
- caliper
- hex drivers
- multimeter
- appropriate electronics and displacement measurement tools
Component illustration
- 1Motor stage
- 2Transmission
- 3Output travel
- 4Tendon interface
Control architecture
- 01Control program
- 02Verified drive interface
- 03Actuation channel
- 04Tendon / continuum mechanism
Mechanical preparation and assembly
Use the procurement spreadsheet to reconcile each actuation channel with its CAD and assembly PDF. Manufacture the structural parts in the documented material, insert purchased hardware and verify alignment of the moving stage. Assemble one channel before duplicating it.
Electrical setup and calibration
Follow the released electrical diagram and identify motor and feedback connections. Mark the mechanism's usable travel, check the supply polarity and leave all channels disconnected until the chosen controller is verified. The actuator is not a complete continuum robot.
Software setup and programming
Inspect the released control information and select matching firmware where provided. Start by measuring unpowered input-to-output motion; test one unloaded channel only with an independently verified current and travel limit. A continuum arm requires separate backbone, tendon layout and kinematics.
First test and acceptance criteria
Measure actuator displacement and repeatability independently. A working actuator channel does not establish a safe full-arm controller; integration requires further mechanical constraints, sensing and calibration.
Programming and configuration example
Use independently measured unloaded channel travel. The example measures repeatability only and is not a published actuator-control API.
import statistics
# Offline repeated-displacement analysis in millimeters.
values = [float(v) for v in input('Measured travel samples (mm): ').split()]
assert len(values) >= 2
print('Mean travel:', statistics.mean(values))
print('Sample repeatability SD:', statistics.stdev(values))Troubleshooting
If unloaded travel varies, verify transmission alignment, friction and the measurement method. Do not attach a continuum backbone until actuator repeatability and safe travel have been independently established.
Technical reference: project release documentation. The assembly references above provide the revision-specific drawings and BOM. Examples are editorial walkthroughs or documented commands; they have not been physically tested by TechniaHQRobot.
What the open hardware is for
The project demonstrates a reconfigurable actuator bank with channels for tendon-driven continuum robots. An optional central working channel can accommodate instruments or cameras depending on the configuration.
Different robots require different numbers of channels, cable routes, end-effector mountings and control policies. The official example should be treated as one mechanical reference.
A documented fabrication package
The repository lists a step-by-step assembly PDF, an Excel BOM, SolidWorks source models and printable parts. A linked full assembly video shows the order of physical components.
Separate printed mechanisms from purchased motors, screws, bearings and cable hardware in your cost estimate. Printed geometry does not replace actuation and sensing hardware.
Commissioning and limits
Before tensioning cables, measure the neutral length and joint workspace of the attached continuum robot. Drive each module separately and inspect tendon friction or slipping.
The source repository does not supply a universal teleoperation or force-control performance number across different robot geometries.
Tendon channels, print files and component lists
Answers are based on published source material and project documentation. Their order does not represent search volume.
01Is this a complete robot I can print and deploy?
No. It is a modular actuator platform intended for use inside a larger continuum robot or other high-DOF assembly.
Sources Official project documentation
02Are STL and SolidWorks files available?
The official hardware repository publishes both CAD and printable parts alongside the assembly documentation.
Sources Official project documentation
03Where is the bill of materials?
The repository links an Excel parts list. It is intended for sourcing the actuation modules rather than a complete application-specific robot.
Sources Official project documentation
04How do I assemble the modules in the right order?
Use the official step-by-step PDF with the full actuation-assembly video; their illustrations show orientation and subassembly sequence.
Sources Official project documentation
05Will the sample layout fit any continuum robot?
No. The lab describes a reconfigurable design. Channel count, tendon paths and mechanical interfaces must be chosen for the target robot.
Sources Official project documentation
06What are the design's reuse rights?
The lab publishes its CAD, print files and assembly materials under the MIT license. Check separate software packages before assuming their terms match.
Sources Official project documentation
Unified Continuum Robot Actuation: parts cost, software updates and maintenance
This practical ownership section complements the original assembly and programming instructions. Public files do not guarantee that all components can still be purchased or that every build is supported.
| Item | Project record |
|---|---|
| Cost record / BOM target | No complete current independent BOM total |
| Software licence | MIT (hardware documentation and designs) |
| Hardware licence | MIT (repository) |
| Simulation availability | Separate software resources referenced by official hardware repository |
| Build difficulty | Advanced |
How to obtain the robot or its parts
Use the Unified Continuum Robot Actuation documentation and hardware release to identify whether an assembled product, kit or self-sourced parts are offered. Price the matching revision, not a photograph or an old bill of materials. Include actuators, controller, supply, wiring, tools, fabrication, shipping, tax and spare parts. A historical BOM target is not a current delivered quote.
- Project documentation
- Source repository and version history
- CAD / fabrication files
How the hardware and software work together
Mechanical path: Motor stage → Transmission → Output travel → Tendon interface.
- Control program
- Verified drive interface
- Actuation channel
- Tendon / continuum mechanism
Feedback, fault detection and the approved stop function constrain the command path.
Inspect the released control information and select matching firmware where provided. Start by measuring unpowered input-to-output motion; test one unloaded channel only with an independently verified current and travel limit. A continuum arm requires separate backbone, tendon layout and kinematics.
Install, update and recover the software
Keep the exact hardware revision, repository commit, operating system, dependencies, controller firmware and calibration in a local build manifest. Read the project’s setup instructions before installing. Use an isolated environment and a separate checkout for upgrades; compare release notes, regenerate only the documented configuration, and first repeat a simulation or read-only test. Back up calibration and original firmware files where the project supports it. Restore only a documented compatible release if the new version fails.
Project-specific verification: Measure actuator displacement and repeatability independently. A working actuator channel does not establish a safe full-arm controller; integration requires further mechanical constraints, sensing and calibration.
Power, battery replacement and cycle life
An actuation test rig has a selected external drive supply, not an established complete mobile robot pack.
A fixed external power supply is not a rechargeable pack. Battery runtime and charge-cycle count are not applicable to a mains-powered configuration. If a mobile conversion adds a pack, it needs its own rated power system.
Common problems, wear and service plan
| When | Inspection and evidence |
|---|---|
| Before operation | Inspect tendon routing, transmission wear and output travel; record force/displacement and hysteresis before and after maintenance. |
| After a fault or impact | Follow the released electrical diagram and identify motor and feedback connections. Mark the mechanism's usable travel, check the supply polarity and leave all channels disconnected until the chosen controller is verified. The actuator is not a complete continuum robot. |
| After software or parts change | Record versions and replaced part serials; compare the same approved test with the earlier baseline. Stop on new errors or unexpected movement. |
| At manufacturer service intervals | Use the documented interval and authorized service procedures. No universal calendar or lubricant is assumed. |
| At end of service | Ask about spare-part availability, data removal, battery take-back and local electronics recycling. |
What is not established by the published files
The project documentation must provide any claimed rated service life, battery cycle endurance, duty limits, warranty and repair intervals for the exact hardware. Without a cited endurance test, report those values as not established, not zero and not an estimate. For a DIY build, keep a parts-replacement log and report conditions when measuring reliability.
Original documentation
- Assembly video and project overview
Found a changed specification? Submit a correction with its source ↗